OME6130 supports transparent DCC capabilities which allows the NE to
pass-through DCC bytes (E1, F1, D1-D3, E2, D4-D12) used by other network
elements. This functionality provides additional integration capabilities into an
existing network without affecting the current DCN configuration.
Remote access to an OME6130 NE can be achieved through asynchronous
RS-232 modem connection through the serial M1/F1 communication port.
OAM&P Ports
This section describes the ports which can be used to perform OAM&P
operations on an OME6130 network element.

M1/F1 port

OME6130 shelf supports a serial communication port which can operate under
the following applications:

LAN port (LAN-1-6)

The OME6130 shelf supports a 10/100BT Ethernet port on the OAM circuit
pack to interface with the external DCN.
It auto-senses the operating speed (10 Mbit/s or 100 Mbit/s), but operates only
at half-duplex mode.
The LAN port is a Medium Dependent Interface (MDI), which requires a
straight-through cable for connection to a hub or switch, and a crossover cable
to a DCN router.
Point-to-point (PPP) - asynchronous RS232 communication with external
modem.
User Data Channel (UDC) - asynchronous 64 kbps clear channel using the
F1 byte of the regenerator section/section overhead. The F1 byte user data
channel is supported only for the STM-1/4 interfaces of the 2x155/622M
aggregate circuit pack.
Planning Guide NT6Q92MA Rel 1.0 Iss 1 Standard September 2006
Appendix A: Data communications planning 10-3