Environmental specifications

The following section outlines the environmental specifications including:

Operating environment specifications

Table 7-34
Table 7-34
Operating environmental specifications for OME6130 system
Attribute
Normal operating
temperature
Short term operating
temperature
Normal operating
humidity
Operational vibration 0.1 g from 5 to 100 Hz and
Storage temperature
Handling shock
Transportation
vibration
operating environment specifications
storage and transportation specifications
outlines the OME6130 operating environment specifications.
Condition
o
o
0
C to 50
C
o
o
-5
C to 55
C
(not more than 96 consecutive
hours and a total of not more
than 15 days in a year)
5% to 90% RH
(for Telecordia GR-63-CORE,
this also meets the short term
relative humidity specification)
return to 5 Hz at a rate of 0.1
octave/minute
o
o
-40
C to 70
C
Packaged and unpackaged
criteria (by weight) per
specification
Sinusoidal, random, and
non-stationary per respective
specifications
Planning Guide NT6Q92MA Rel 1.0 Iss 1 Standard September 2006
Technical specifications 7-35
Test method and specification
• Telcordia GR-63 CORE (NEBS)
• ETSI EN 300 019-2-3 Class 3.1 (E)
• Telcordia GR-63 CORE (NEBS)
• Telcordia GR-63 CORE (NEBS)
• ETSI EN 300 019-2-3 Class 3.1 (E)
• Telcordia GR-63 CORE (NEBS)
• ETSI EN 300 019-1-1 Class 1.2
• Telcordia GR-63 CORE (NEBS)
• Telcordia GR-63 CORE (NEBS)
• ETSI EN 300 019-2-2 Class 2.2 and Class 2.3
• Telcordia GR-63 CORE (NEBS)
• ETSI EN 300 019-2-2 Class 2.3