8-3 Precautions for Wiring

(1) Wiring to power connector and terminal block
100/200 V Sizes A–D:
Power supply (Single-phase)
• When used in single phase
power supply, make sure to
connect it between terminals
L1, L3.
Power supply (3-phase)
R1.0
MCCB
External regenerative
resistor
Short cable
Detach it when using an
external regenerative resistor
(Sizes C,D).
Red
White
Black
Green
12–24 VDC
Thermal protector with built-in
external regenerative resistor
OFF
ON
ALM
L
XA
L1
Main power
L2
supply
L3
MC
L1C
Control
power supply
L2C
XB
B1
B3
B2
U
Motor
V
Connection
W
X4
ALM
3
ALM+
4
ALM-