Usb Connector X1 - Panasonic A5N9 Series Reference Specifications

Ac servo driver
Table of Contents

Advertisement

[7] Size H of 200 V and 400 V System
Terminal symbol
Name
200 V
Control power
supply input
Dynamic brake
resistor control
terminal
Main power
supply input
Regen resistor
connection
Motor
connection
Earth
• Refer to section 9-3 for the tightening torque of the screw.
• Tighten M5 terminal block cover fixing screw with the 0.4 N•m torque.

7-2 USB Connector X1

By connecting to the PC through USB interface, various operations such as setting/changing of parameters, monitoring of
control state, referencing of error/history, and saving/loading of parameters can be performed.
Name
USB signal
For manufacturer use
Signal ground
R1.0
Terminal no.
(left to right)
400 V
L1C
24V
1
L2C
0V
2
DB1
3
DB1
DB2
DB2
4
L1
L1
1
L2
L2
2
L3
L3
3
B1
B1
4
B2
B2
5
NC
NC
6
U
U
7
V
V
8
W
W
9
Connector
Symbol
pin no.
VBUS
1
D-
2
D+
3
4
GND
5
200 V : Single phase 200–230 V
400 V : 24 V dc +/- 15%
• Connect when it is necessary to control the MC for external dynamic brake
resistor (prepared by the user).
• Impress the voltage AC300V or less or DC100V or less between DB1 and
DB2.
200 V : 3 phase 200–230 V
400 V :
3 phase 380–480 V
• When tripped by a regenerative load protect error, connect an external
regenerative resistor (the value set by parameter Pr0.16 and prepared by the
user) across B1 and B2.
Note) Do not connect any wire to the NC terminal.
Connect each phase of the motor winding.
U: U phase V: V phase W: W phase
There are 2 grounding terminals.
Connect the one terminal to ground, and the other to the E terminal of a motor.
Do not connect more than one wire to a grounding terminal.
Communicate with a computer
• Do not connect
• Signal ground
Motor Business Unit, Appliances Company, Panasonic Corporation
No. SX-DSV02308 - 24 -
Description
+ 10%
50/60 Hz input
- 15%
+ 10%
50/60 Hz input
- 15%
+ 10%
50/60 Hz input
- 15%
Description