8. Wiring
8-1 Used Cables and Maximum Cable Lengths
Name
Main power supply
Control power supply
Motor connection
Earth cable
Scale connection
I/O connection
RTEX connection
Note 1:
When using Tyco Electronics AMP connectors (172167-1, 172189-1) as motor junction connector,
maximum applicable conductor size is 1.3 mm
Note 2:
Refer to 8.3 (5) Connection to connectors X2A and X2B.
8-2 Cable Side Connector
Connector symbol
X3
X4
X5
X6
X7
Use connectors listed above or equivalents.
R1.0
Maximum cable
Symbol
length
L1, L2, L3
L1C, L2C
U, V, W,
20 m
1 m
X6
20 m
X4
3 m
X2A/X2B
100 m (Note 2)
Part name
Connector
Solder plug
(soldering type)
Shell kit
Connector
Connector
Connector
Connector pin
Refer to the associated specification available separately.
HVSF 0.75 mm
Refer to the associated specification available separately.
Refer to the associated specification available separately.
Overall twisted shielded pair
Core wire: 0.18 mm
Twisted shielded pair (STP) cable of category 5e or better
2
.
Part number
2013595-1
10126-3000PE
10326-52A0-008
MUF-PK10K-X
3E206-0100KV
3E306-3200-008
51004-0600
50011-8100
Motor Business Unit, Appliances Company, Panasonic Corporation
No. SX-DSV02308 - 32 -
Used cable
2
(Note 1)
2
or larger
Manufacturer
Tyco Electronics
Sumitomo 3M
J. S. T. Mfg
Sumitomo 3M
Molex