In case the two openings in the rear wall wouldn't be feasible, act as shown in
point 2 (Fig. 3b) or point 3 (Fig. 3c).
2
REAR AND SIDE WALLS AVAILABLE FOR CREATING VENTILATION
OPENINGS.
The first opening must have a minimum height of 120mm (4,7in) and
must extend to the whole width of the refrigerator.
The second must be positioned opposite the condenser and must have
a minimum size of 120 x 120mm (4,7x4,7in). The minimum distance
between the back of the refrigerator and the recess must be at least
75mm (2,9 in) (Figure 3b).