Surge Immunity Requirements As Per Iec 61000-4-5 - EM TEST compact NX5 Series Operation Manual

Ultra-compact simulator and its system modules
Table of Contents

Advertisement

EM TEST
6.2.

SURGE Immunity requirements as per IEC 61000-4-5

Test Level
Open circuit voltage
Short circuit current
Wave shape open circuit
coupling
Front time tr
Pulse duration
Wave shape short circuit
coupling
Front time tr
Pulse duration
Polarity
Repetition rate
Events preselection
Counter
Trigger
Trigger of pulses
Synchronization
Resolution
Measurements
CRO
CRO Û
CRO Î
Accuracy CRO V , CRO I
CRO Û/I Z measuring instrument > 1 MΩ
Peak voltmeter
Peak current meter
Current limiter setting
Output
Direct HV-COM
Coupling network
DUT supply
Test Routines
Quick Start
Standard test routines
separated to (AC / DC)
Extended Tests
* depends on charging voltage
Operating Manual
compact NX5 (16A Models)
160 V – 5000 V ± 10% Step 1 V
80 A – 2500 A ± 10%
18 F line to line
9 F line to ground
1,2 s ± 30%
1,2 s ± 30%
50 s +10 μs/-10 μs
50 s +10 μs/-25 μs
18 F line to line
9 F line to ground
8 s ± 20%
2.5 s ± 30%
20 s ± 20%
25 s ± 30%
Pos., Neg., Alt
max. 1 Hz (1 s* - 9999 s)
1 - 99'999
1 – 1'000'000
AUTO, MAN, EXTERN
0 - 360° (16 – 500 Hz)
Asynchronous = 0°
5 V Trigger
10 Vp at 5 kV
10 Vp at 2.5 kA
± 10%
5000 V
2500 A: Display  1 Digit  20 A
10 A...3000 A step 10 A
HV-Banana connector, Zi = 2
L – N with Z = 2
L-PE, N-PE, L+N-PE with Z = 12
AC 300 V / 16 A / 50/60 Hz
DC 300 V / 16 A
Immediate start, all parameters adjustable during a running test
IEC 61000-4-5 one level: Selectable level 1 to 4
IEC 61000-4-5 all levels: Starts from lowest level to selected level
IEC 61000-4-5 level 3
IEC 61000-4-5 level 4
EN 61000-6-1 Generic (AC / DC)
EN 61000-6-2 Generic
Voltage iteration stepwise: Voltage level V after n pulses by V
Angle iteration stepwise: Change phase angle A after n pulses by A
Angle random iteration: Random phase angle A after n pulses
V 1.06
compact NX5 (32 A Models)
18 F line to line
1,2 s ± 30%
50 μs +10 μs/-15 μs
a reference signal is connected to the Sync input.
no
x
Compact NX5
9 F line to ground
1,2 s ± 30%
50 μs +10 μs/-30 μs
9 F
18 F
x
x
x
70 / 143