EM TEST compact NX5 Series Operation Manual page 121

Ultra-compact simulator and its system modules
Table of Contents

Advertisement

EM TEST
12.9.1.4.
Technical Data V 4780 models
Design
Input:
Voltage
Frequency
Tap selection
Remote control
Output:
Voltage tap [% Unom]
Current Imax.
Power
Fuse
Weights and measures
Dimensions
Weights
Temp Ambiance
12.9.1.5.
Setup V4780
The output voltages are available at
safety banana plugs. For safety
reasons the related safety cables
shall be used.
The power supply input is realized
with a power connector for L, N and
PE. The voltage shall be 100% of
the nominal voltage Vn.
Connection V 4780 / V 4780 S2
Connection V 4780 S1
Operating Manual
Tapped auto-transformer with 40%, 70%, 80%, 100 % output voltage
Uin: max. 250 V
50/60Hz
manually (V4780 ) banana plugs for 40%, 70%, 80%
0.10V dc (V4780 S2) for 40%, 70%, 80%
120 % (V4780 S1)
100 %
80 %
70 %
40 %
V 4780, S1, S2
16 A
4.1 kVA
2x 16 A
95 x 170 x 190 mm (H x B x T)
ca. 7 kg
10C - 35C
V 1.06
V 4780 S3
32 A
8.2 kVA
2x 35 A
200 x 170 x 190 mm (H x B x T)
ca. 14 kg
10C - 35C
Compact NX5
121 / 143