10.3.3.
HV-COM output (18 µF capacitor)
The HV – COM output includes a configurable output capacity with 18 µF. Using EM TEST coupling-decoupling
networks, the coupling capacitor is part of the CDN. For other applications e.g. pulsed surge magnetic field or a
surge verification requires an 18 µF capacitor in the circuit. The NX generator includes a configurable 18 µF
capacitor at the HV – COM output.
Application with 18 µF capacitor
Pulsed magnetic field application to a single turn antenna as per IEC 61000-4-9
-
-
Generator pulse verification at the NX5 HV-COM output
Pulse verification at the coupler HV-COM output
-
Application to any external CDN not from EM TEST manufactured
-
Application without 18 µF capacitor
-
Using a coupling decoupling network from EM TEST.
REMARK:
All CDN from EM TEST includes a built in coupling capacitor. The values
are 18 µF, 9 µF, 0.5 µF or any other special value according the
application.
Capacitor setting
For set the 18 µF capacitor use menu
MENU / SETUP /
Operating Manual