10. Remove the white plastic side connector from the potentiometer
by pressing on the connector tab. (see Figure 85).
11. Replace the XLO valve if needed.
12. Detach the XLO valve from the potentiometer by using a small
flat-blade screwdriver to gently remove the XLO valve from the
potentiometer standoffs. Then slide the potentiometer off the valve
stem (see Figure 86).
Gas Leaks
With electrical power off, carefully check for gas leaks at each gas
component that was removed, replaced, or otherwise serviced using a
gas leak detector or bubble test. For XLO valves, you may need the
electrical power to be on when testing for gas leaks. Use extreme
caution when performing gas leak testing on XLO valves with the
electrical power on.
Figure 85: Side Connector Tab
1
Harness connector tab
58300000157422_ARA_EN_A
PRD304EG, PRD364EDG, PRD364EDPG, PRD364ELG, PRD366EG, PRD366EPG, PRD484ECG, PRD484EEG, PRD486EDG, PRD486EDPG, PRD486ELG
Figure 86: Removing the XLO Valve from the Potentiometer
Page 46 of 95