The Anderson Powerpole™ connector contains 45 Amp pins to minimize voltage drop during transmit. The RED
connection should be connected to the positive (+) lead of the power source. The BLACK connection should be
connected to the negative (-) lead of the power source.
I - If you choose to use your own Powerpole cabling, be sure to properly size the wire and the Powerpole connector to
minimize voltage drop during transmit. Excessive voltage drop can cause lower transmit power output levels.
There are two internal fuses in the HAMlab. One is protecting whole system while the other one is just for the
transceiver. If you ever need to replace the internal fuse, remove the top cover and the shield of the power board.