5.2.2

BUS OUT - RS 232 and switching inputs/outputs 5 to 8

The RS 232 interface is used to output test results, see webConfig manual for details.
BUS OUT
FE
IO5
7
Tx
M12 socket
(A-coded)

Table 5.2:

 Preferably, use the "KS S-M12-8A-P1-..." ready-made cables, see table 9.8 "BUS OUT
cables for the LSIS 4xxi" on page 55:
If using self-made cables, observe the following notice:
Notice for connecting the RS 232 interface!
Ensure adequate shielding. The entire connection cable must be shielded and earthed.
RS 232 cable assignments
Host
GND
Rx
Figure 5.5:
Switching input / output
The freely configurable switching inputs/outputs are described in chapter 5.2.1.
Leuze electronic
BUS OUT (8-pin socket, A-coded)
Pin
IO6
GND
IO7
IO8
Rx
Thread

Pin assignment BUS OUT

Shield
Tx
up to 10m
RS 232 pin assignments
Name
1
IO5
Configurable switching input/output 5
2
IO6
Configurable switching input/output 6
3
GND
Negative supply voltage 0VDC
4
IO7
Configurable switching input/output 7
5
IO8
Configurable switching input/output 8
6
Rx
Rx signal (RS 232)
7
Tx
Tx signal (RS 232)
8
FE
Functional earth
FE
Functional earth (housing)
BUS OUT
IO6
FE
IO5
7
Tx
Rx
LSIS
4xxi
Electrical connection
Remark
GND
IO7
IO8
34