5.2.3

SERVICE - Ethernet host/configuration interface

The LSIS
4xxi
process data.
SERVICE
TD+ 1
M12 socket
(D-coded)

Table 5.3:

 Preferably, use the ready-made "KS ET-M12-4A-P7-...", "KSS ET-M12-4A-M12-4A-P7-..."
and "KSS ET-M12-4A-RJ45-A-P7-..." cables, see "Accessories for the host/service inter-
face" on page 56.
If using self-made cables, observe the following notice:
Notice for connecting the Ethernet interface!
Ensure adequate shielding. The entire connection cable must be shielded and earthed. The
RD+/RD- and TD+/TD- wires must be stranded in pairs.
Use at least CAT 5 cables for the connection.
Ethernet cable assignment
SERVICE
RD+
TD
SH
RD
Figure 5.6:
Leuze electronic
makes an Ethernet interface available for configuration and for transferring
SERVICE (4-pin socket, D-coded)
Pin
RD+
2
TD-
3
4
RD-
Thread

SERVICE pin assignments

Twisted pair
TD+
Twisted pair
Cable assignments - SERVICE on RJ-45
Name
1
TD+
Transmit Data +
2
RD+
Receive Data +
3
TD-
Transmit Data -
4
RD-
Receive Data -
FE
Functional earth (housing)
TD+ (1)
TD- (2)
RD+ (3)
RD- (6)
The depicted core colors apply only for Leuze cables
and are not compliant with EIA/TIA 568A and EIA/TIA 568B.