  • Page 1 LCAM 408i Industrial Ethernet Camera User Manual Revision 1.2...
  • Page 2 DISCLAIMER Copyright © 2016 Leuze electronic GmbH+Co. KG. The information, data, and figures in this document including respective references have been verified and found to be legitimate. In particular in the event of error they may, therefore, be changed at any time without prior notice. The complete risk inherent in the utilization of this document or in the results of its utilization shall be with the user;...
  • Page 3 Canadian department of communications statement This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. This class B digital apparatus complies with Canadian ICES-003. SAFETY INFORMATION Electrical safety To prevent electrical shock hazard, disconnect the power cable from the electrical outlet before...
  • Page 4: Table Of Contents

    CONTENTS Hardware M12 connectors Pin definition Ethernet connector Pin definition Power connector Switching off Optics Mounting the camera 1.6.1 With screws 1.6.2 At a Rod (14-20mm) with the BT 56-1 or BT 300-1 1.6.3 With a mounting angle First Steps What’s needed What to do Web Interface...
  • Page 5: Hardware

    Hardware This manual covers the industrial LCAM 408i with MJPEG streaming capabilities and its software. The LCAM 408i has outer dimensions of approx. 75 mm (L), 55 mm (W), 113 mm (H). M12 connectors The M12 connectors on the bottom side are used for Ethernet connection (named with SERVICE) and the other for Power Supply (named with PWR).
  • Page 6: Pin Definition Power Connector

    3,40 x 2,60 m @ 2 Meter distance Mounting the camera There are different options to mount the LCAM 408i 1.6.1 With screws The camera can by mounted to a flat surface with four M4 * 4 screws. There is no preferred mounting direction.
  • Page 7: At A Rod (14-20Mm) With The Bt 56-1 Or Bt 300-1

    1.6.2 At a Rod (14-20mm) with the BT 56-1 or BT 300-1 1.6.3 With a mounting angle The camera can mount to the BT 300W and adjust in different directions...
  • Page 8: First Steps

    Start streaming video  When finished, start the streaming client as shown below. This document gives an introduction into the use of the LCAM 408i with MJPEG streaming. The Software API is available on request. Web Interface Changing Camera IPs Under *Network settings* you can choose between static address assignment and DHCP mode.
  • Page 9: Default Network Settings

    Default network settings The default factory settings for network are: DHCP 192.168.60.101 This is in one of the private IP spaces IP Mask 255.255.0.0 Gateway Not needed for test, change for large nets DNS server Not needed for test, change for large nets Order number Camera-individual Default login data...
  • Page 10: Camera Settings

    Camera Settings Camera settings can only be changed by the web interface. It is possible to change the exposure time, the gain of the different color channels, image flipping and Bayer mode. Gain values for the color components can be used for color correction. Exposure sets the exposure time of the sensor.
  • Page 11: Streaming

    Streaming To watch the streamed image with the VideoLANClient VLC on a 64-Bit Windows system use the line: "C:\Program Files (x86)\VideoLAN\VLC\vlc.exe" tcp://IPaddress:5001 --network-caching=0 Fill in the IP address of the camera and adjust the path to vlc.exe as needed. The typical setting in VLC looks like this: Be sure to set caching and IP address if not done so on the command line.
  • Page 12 3.6.2 RTSP-Protocol (Softwareversion 45d1eab) The LCAM supports the livestream on the RTSP-Protocol. You can use the with e.g. Siemens Comfort-Panel rtsp://192.168.60.101:554/jpeg (It shows the Default IP-Adrdess of the LCAM) Important: The RTSP-Protocol allow maximum Pixels up to 2000. Therefore we recommend to use as maximum the picture resolution of 1920x1080 pixel (FullHD) 3.6.3 Live stream in the browser (Softwareversion 45d1eab)
  • Page 13: Menus

    Menus The LCAM 408i has an internal web server that has the following menus. Administration 4.1.1 Factory reset 4.1.2 Password selection Here one of the two possible passwords can be selected to be changed or set.
  • Page 14: Password Setting

    4.1.3 Password setting Here passwords are changed and set. 4.1.4 Reboot System reboot is done without further data and should be finished after a minute.
  • Page 15: Update

    4.1.5 Update The update process needs a path to a firmware file. Image settings 4.2.1 Automatic Exposure Here, image sizes and frame rates can be selected. Image size is limited by sensor parameters, however, smaller images can be selected. The LCam supports two independent streams with the same content on different ports, one full-size and one scaled-down.
  • Page 16 Bayer mode because the flipping will change the starting pixels the Bayer mode the mode has to be adjusted if flipping is done. In streaming mode this setting has no effect Sleep between only used in webcam mode, not in streaming mode snaps Automatic gain enables the automatic exposure control...
  • Page 17: Manual Exposure

    4.2.2 Manual Exposure In manual exposure mode, gain and exposure parameters can be set. At the moment camera settings can only be changed by the web interface. It is possible to change the exposure time, the gain of the different color channels, image flipping and Bayer mode. Gain values for the color components can be used for color correction.
  • Page 18 Exposure sets the exposure time of the sensor Gain global gain for all color channels Red gain gain for all red pixels Blue gain gain for all blue pixels Green gain 1 and 2 gain for green pixels in even and in odd lines, values should be identical horizontal and can be used to correct the image orientation according to...
  • Page 19: Network

    Network Here you can choose between static address assignment and DHCP mode. For static IP, fill out the fields as needed. And press "Save data". To use the new settings, pressing "Restart network" is needed. For DHCP mode, no addresses are needed, they are obtained from the DHCP server.
  • Page 20: Menu General Appearance

    Menu general appearance This image shows the general menu structure. About Menu The “About” screen shows data needed for service enquiries or for searching a camera in the network.
  • Page 21: Appendix

    Appendix Data sheet key data Below you find the key data for the sensor.