7.4

Operation

Shown here is an example describing important operating procedures in detail.
Parameter enabling
During normal operation parameters can only be viewed. If parameters need to be changed,
the ON menu item in the Parameter enabling menu must be activated. To do this proceed
as follows:
Parameter
Parameter handling
Display settings
Program selection
Ethernet
Parameter handling
o Parameter enable
 Parameters to default
Parameter enable
OFF
o ON
Standard ----- Unit
OFF
|
Parameter enable
OFF
O ON
Standard ----- Unit
OFF
|
Leuze electronic
|
|
ESC
ESC
In the Parameter menu, use the
Parameter handling menu item.
Press the enter button to enter the Parameter handling
menu.
In the Parameter handling menu, use the
select the Parameter enable menu item.
Press the enter button to enter the Parameter enable
menu.
In the Parameter enable menu, use the
select the ON menu item.
Press the enter button to switch on parameter enabling.
The PWR LED lights up orange. You can now set
individual parameters via the display.
Press the ESC button twice to return to the main menu.
LSIS
4xxi
Display and control panel
buttons to select the
buttons to
buttons to
48