Restore To Factory Setting - netvox R718H2 User Manual

Wireless 2-input pulse counter interface
Hide thumbs Also See for R718H2:
Table of Contents

Advertisement

Configure pulse filtering time (default FilterTime is 10ms):
SetFiltertim
eReq
SetFiltertim
eRsp
R718
H2
GetFiltertim
eReq
GetFiltertim
eRsp
Battery voltage Report default variation: Mintime = Maxtime = 1hr, reportchange = 0x01 (0.1V)
Note:
Input pulse width greater than 100ms can be accurately counted
The device send data cycle is subject to the programming configuration.
The interval between two reports must be the minimum interval.
Data report configuration and sending period are as following:
Min Interval
(Unit:second)
Any
number
between 1~65535

5. Restore to Factory Setting

R718H2 saves data including network key information, configuration information, etc. To restore to
factory setting, users need to execute below operations.
1. Press and hold function key for 5 seconds till the green indicator flashes and then release; LED
flashes quickly 20 times.
2. R718H2 is at off mode by default setting after restoring to factory setting.
Note: The device operation of turning off is the same as the device restore factory settings.
0x03
FilterTi
me(1byt
e,Unit:1
ms)
0x83
Status(0
x00_suc
cess)
0x3F
0x04
0x84
FilterTi
me(1byt
e,Unit:1
ms)
Max Interval
(Unit:second)
Any
number
between 1~65535
Reserved (8Bytes,Fixed 0x00)
Reserved (8Bytes,Fixed 0x00)
Reserved (9Bytes,Fixed 0x00)
Reserved (8Bytes,Fixed 0x00)
Reportable
Current
Change
Reportable Change
Report
Can not be 0.
per Min Interval
6
Current
Change <
Change≥
Reportable Change
Report
per Max Interval