5. Restore to Factory Setting
Operation method: press and hold the button for 5 seconds and the green LED flashes for 20 times,
and R718CK2/T2/R2 will be turned off after successful erasure.
6. Sleeping Mode
R718CT2/CK2/CR2 is designed to enter sleeping mode for power-saving in some situations:
(A) While the device is in the network → the sleeping period is one hour. (During this period,
if the reportchange is larger than setting value, it will wake up and send a data report).
(B) When it is not in the network → R718CT2/CK2/CR2 will enter sleeping mode and wake
up every 15 seconds to search a network to join in the first two minutes. After two minutes, it
will wake up every 15 minutes to request to join the network.
If it's at (B) status, to prevent this unwanted power consumption, we recommend that users
remove the batteries to power off the device.
7. Low Voltage Alarming
The operating voltage threshold is 3.2V. If the voltage is lower than 3.2V, the device will send a
low-power report to the Lora network.
8. Installation
Thermocouples have positive and negative poles, with the + mark on the bare device as the direction,
the second and third holes as a group, the 4th and 5th holes as a group, the 2nd and 4
to the positive (red line) of the thermocouple, the third and fifth holes connect to the negative (black
line) of thermocouples. This product comes with a waterproof function. When using it, you can
attach the back side to the iron surface, or use screws to fix both ends to the wall.
Note: To install the battery, use a tool such as a screwdriver to open the battery cover.