Error messages in the hand-switch display (optional)

Display
Cause
HOT
The controller monitors
the operating time (time-
controlled) and its max.
temperature value was
exceeded.
E00
M1 – Internal error
E01
M2 – Internal error
E02
M3 – Internal error
E12
M1 – Defective
E13
M2 – Defective
E24
M1 – Overcurrent
E25
M2 – Overcurrent
E36
M1 – Not connected
E37
M2 – Not connected
E48
Overcurrent
Motor group 1
E55
Motor group 1 –
Synchronisation lost
E60
Collision detected
E61
Motor replaced
E62
Overcurrent
E63
External sensor or cable
not connected
E64
Authentication error
E65
Overcurrent or
short-circuit
E67
Overvoltage
E70
Change the
drive configuration
(Motor = Drive in the installation column or in the side panel)
Repair
Wait until the controller has cooled off and the "HOT" display has
disappeared. The desk is then operational again.
ATTENTION!
The operating time is calculated only as long as the mains voltage is
applied. If the controller is disconnected from the mains, the most
recent value in the controller is saved!
Pull the mains plug!
and contact the your customer service representative!
Pull the mains plug!
Repair the external short-circuit, check the cable to the monitors for
possible damages
or
Plug in the involved socket of the correct motor.
Put the controller back into operation.
Collision? -> if applicable, repair
Max. load exceeded -> take the load off the desk.
If the error persists, please contact customer service.
The motor is not connected
Check the cable/plug connection to the motors and do a reset
Collision? -> if applicable, repair
Max. load exceeded -> take the load off the desk.
Motor positions too different
If applicable, reduce the load on the desk
Reinitialise the desk (RESET)
Optional ISP and sensor function
Remove cause
Connection to the motor was interrupted or a new motor was
connected
Reinitialise desk (RESET)
Controller – total overcurrent, overload
External crushing protection strip or special add-on module not
connected; if applicable check plug connector
Reinitialise desk (RESET)
If error occurs during drive.
Collision? Load too heavy?
Pull the mains plug!
and contact the your customer service representative!
Mains or power pack fluctuations?
Pull the mains plug and wait at least 5 seconds. Then reinitialise the
desk (RESET)