Absolute Ac Non-Sine Voltage - Fluke 5790B Operator's Manual

Ac measurement standard
Hide thumbs Also See for 5790B:
Table of Contents

Advertisement

5790B
Operators Manual

Absolute AC Non-sine Voltage

[1]
Specifications apply for non-sinusoidal inputs with crest factor <3.0 and with harmonic content band-limited to <1 MHz.
[2]
Crest factor limited to <2.3 for signals greater than 75 % of full scale RMS.
1-14
[1]
Range
2.2 mV
7 mV
22 mV
70 mV
220 mV
700 mV
[2]
2.2 V
7 V
[2]
22 V
70 V
Frequency Range
10 Hz - 45 Hz
45 Hz - 1 kHz
1 kHz - 20 kHz
20 kHz - 100 kHz
10 kHz - 45 Hz
45 Hz - 1 kHz
1 kHz - 20 kHz
20 kHz - 100 kHz
10 Hz - 45 Hz
45 Hz - 1 kHz
1 kHz - 20 kHz
20 kHz - 100 kHz
10 Hz - 45 Hz
45 kHz - 1 kHz
1 kHz - 20 kHz
20 kHz - 100 kHz
10 Hz - 45 Hz
45 Hz - 1 kHz
1 kHz - 20 kHz
20 kHz - 100 kHz
10 Hz - 45 Hz
45 Hz - 1 kHz
1 kHz - 20 kHz
20 kHz - 100 kHz
10 Hz - 45 Hz
45 Hz - 1 kHz
1 kHz - 20 kHz
20 kHz - 100 kHz
10 Hz - 45 Hz
45 Hz - 1 kHz
1 kHz - 20 kHz
20 kHz - 100 kHz
10 Hz - 45 Hz
45 Hz - 1 kHz
1 kHz - 20 kHz
20 kHz - 100 kHz
10 Hz - 45 Hz
45 Hz - 1 kHz
1 kHz - 20 kHz
20 kHz - 100 kHz
1-Year, tcal ±5 °C,
±(% of reading + µV)
0.1 + 1.3
0.1+ 1.3
0.17+ 1.3
0.5 + 2.5
0.1 + 1.3
0.1 + 1.3
0.17 + 1.3
0.5 + 2.5
0.1 + 1.3
0.1 + 1.3
0.17+ 1.3
0.5 + 2.5
0.1 + 1.5
0.1 + 1.5
0.17 + 1.5
0.5 + 2.5
0.1 + 1.5
0.1 + 1.5
0.17 + 1.5
0.5 + 2.5
0.1 + 1.5
0.1 + 1.5
0.17 + 1.5
0.5 + 2.5
0.1
0.1
0.17
0.5
0.1
0.1
0.17
0.5
0.1
0.1
0.17
0.5
0.1
0.1
0.17
0.5