● Ignoring Interval: The system does not produce
event log entries or issue remote notifications
regarding motion detected for the time specified
after the initial motion was detected. Set the value
between 1 sec and 5 secs or choose Never.
Ignoring Interval does not affect motion detection
recording.
● Daytime Setup: Specify when daytime starts and
ends. Adjust the time frame in 15-minute increments.
Times outside the specified range will be assumed as
nighttime by the system.

Video-Analytics_Trip Zone

● No.: Select which cameras to apply Trip Zone to.
● Sensitivity: Set daytime and nighttime sensitivity
settings between 1 (Low) and 5 (High).
● Zone: Define the motion detection block.
You can use the mouse to drag the zone and then select,
clear, or reverse the selection.
From the zone selection screen, right-click on the mouse
to open up the Zone Setup menu.