Troubleshooting
8.2. Error Messages
Error message
Gate state says ERROR
On/off settings are linked to
the implement. Please select
an implement name before
modifying Section Control
On/Off Settings.
The following gates are in
need of repositioning.
This feature is currently
disabled.
There are disabled gates in
the system. You may re-
enable them in the
diagnostics menu.
There are X motor
controllers that haven't been
mapped to a location.
600890-000059, rev 1.1
Troubleshooting steps
1. Reposition the gate that has an error.
2. Check for product buildup.
a. Unplug the Engage Zone Control unit bin harness.
b. Remove the bottom meter cover and top lid and clean
product buildup that is impeding gate movement. Refer
to the Engage Zone Control Maintenance Manual
(600840-000047) for cleaning procedures.
c. Re-connect the bin harness.
Make sure that you've selected an implement type and name in
the JD Equipment settings.
1. Reposition the gate that appears red on the screen.
2. Check for product buildup.
a. Unplug the Engage Zone Control unit bin harness.
b. Remove the bottom meter cover and top lid and clean
product buildup that is impeding gate movement. Refer
to the Engage Zone Control Maintenance Manual
(600840-000047) for cleaning procedures.
c. Re-connect the bin harness.
Contact your Intelligent Ag dealer if you repeatedly get the
same error on a gate.
Make sure that Engage Zone Control is enabled on the
Intelligent Ag Settings screen (see Section 2).
1. Tap Config on the right Intelligent Ag navigation.
2. Tap Diagnostics.
3. Tap the arrow buttons until you see the disabled gate.
4. Tap Enable & Reposition.
Navigate to the Serial Number Configuration settings screen
and ensure that all motor controllers have been configured.
Engage Zone Control Operator's Guide
Page 24 of 25
Need help?
Do you have a question about the Engage Zone Control and is the answer not in the manual?