Configuring Engage Zone Control Application
4.4. Viewing work switch status
The work switch status is shown in the top left corner of the Intelligent Ag Gates screen.
When the implement is raised, the work switch icon should appear gray.
When the implement is lowered, the work switch icon should appear green.
If the opposite colors appear, refer to Section 8 for troubleshooting steps.

4.5. Editing JD Section Control settings

Use Time of Flight Compensation measurements to set turn on and turn off times.
1. Navigate to the JD Section Control Settings screen.
a. Tap
b. Tap GS3 (GreenStar).
c. Tap
in the upper right corner.
d. Tap Section.
2. Tap Turn On/Off Settings and input the following time of flight compensation times from
Section 4.2:
Turn on time: the longest Time of Flight Compensation time.
Turn off time: the shortest Time of Flight Compensation time.
IMPORTANT: The turn on times for each operation should all be the same number,
and the turn off times for each operation should all be the same number.
3. Tap Accept.
600890-000059, rev 1.1
in the lower right corner.

Figure 16: JD Section Control On/Off settings screen