Using the System

5. Using the System

5.1. Monitoring Mapping

Navigate to the Mapping or Section Control screen to monitor your seeding.
NOTE: When the implement is raised, the gates won't move and won't map coverage. If
coverage isn't immediately mapping upon exiting headland or previous coverage, either lower
the implement sooner or adjust the work switch triggering point.

5.2. Intentionally Overseeding

Uncheck the Section Control Master box on the Section Control screen if you want to
intentionally overseed (such as when seeding into the headland or near field boundaries).
IMPORTANT: Make sure that all gates are open before unchecking the box.

5.3. Manually Closing or Opening a Section

1. Tap
in the lower right corner.
2. Tap Intelligent Ag.
3. Tap Gates.
4. Tap the number of the section that you want to open or close.
NOTE: Manual changes only stay in effect until the JD task controller issues another command.
To continue to manually control the system, uncheck Section Control Master box on the JD
Section Control screen.
600890-000059, rev 1.1

Figure 17: JD Section Control screen

Figure 18: Manually closing or opening a section

Engage Zone Control Operator's Guide