P434
Digital output function
Arrays
[-01] ... [-02]
Scope of Application
Description
Assignment of functions for the digital output
Note
The parameters which are assigned to the output for standardisation (P435) or
hysteresis P436) do not have any effect for the use of functions which are relevant to
POSICON. In this case the hysteresis is set via parameter P625.
Setting values
Value
Pos : 241 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/POSICON/Safety/P400 bis P499 (POSICON/safety)/P434 / P481 - F unktionen Digitalausgang_Einstellwerte @ 14\mod_1479293302685_388.doc x @ 2304814 @ @ 1
0
20
21
22
23
24
25
26
27
Note: For detailed information about the initial messages see  Section 4.10 "Output messages"
BU 0210 en-3117
Off
Reference
Position reached
Comparative position
Comparative position value
Position array value
Comparative position reached
Comparative position value
reached
Flying Saw Synchronisation
Meaning
The output is not used.
Reference point is available / has been saved
Set position has been reached
Position value in P626 has been reached
Position value in P626 (without consideration of sign) has been
reached.
A value set in P613 has been reached or exceeded.
Comparative position has been reached, as for 22, however with
consideration of P625
Comparative position value has been reached, as for 23, however
with consideration of P625
The slave drive has completed the start phase of the "Flying Saw"
function and is now synchronised with the master axis.