Dimensions Of Flue Gas Outlet Pipe; Length Of The Air And Flue Gas Pipes - REMEHA Quinta Ace 30 Installation And User Manual

High-efficiency wall-hung gas boiler
Hide thumbs Also See for Quinta Ace 30:
Table of Contents

Advertisement

Tab.10
Overview of material properties
Version
Flue gas outlet
Material
Single-wall, rigid
Plastic
Stainless steel
Thick-walled,
aluminium
(1) according to EN 14471
(2) according to EN 1856
(3) according to EN 13501-1
Fig.6
Dimensions of concentric
connection
ød
1
øD
7684359 - v.06 - 10012019
Material properties
With CE marking
(1)
Temperature class T120 or
(2)
higher
Condensate class W (wet)
(2)
Pressure class P1 or H1
Fire resistance class E or bet­
ter
(3)
1
AD-3000962-01
Warning
The coupling and connection methods may vary depending on
the manufacturer. It is not permitted to combine pipes, coupling
and connection methods from different manufacturers. This also
applies to roof feed-throughs and common channels.
The materials used must comply with the prevailing regulations
and standards.
Please contact us to discuss using flexible flue gas outlet
material.
Air supply
Material
Plastic
Stainless steel
Aluminium
4.8.3

Dimensions of flue gas outlet pipe

Warning
The pipes connected to the flue gas adapter must satisfy the
following dimension requirements.
d
External dimensions of flue gas outlet pipe
1
D
External dimensions of air supply pipe
1
L
Length difference between flue gas outlet pipe and air supply pipe
1
Tab.11
Dimensions of pipe
d
(min-max)
1
80/125 mm
79.3 - 80.3 mm
100/150 mm
99.3 - 100.3 mm
(1) Shorten the inner pipe if the length difference is too great.
4.8.4

Length of the air and flue gas pipes

The maximum length of the flue gas outlet and air supply channel vary
depending on the appliance type; consult the relevant chapter for the
correct lengths.
Important
When using bends, the maximum chimney length (L) must be
shortened according to the reduction table.
For adaptation to another diameter use approved transitions
The boiler is also suitable for longer chimney lengths and
diameters other than those specified in the tables. Contact us
for more information.
4 Before installation
Material properties
With CE marking
Pressure class P1 or H1
Fire resistance class E or bet­
ter
(3)
D
(min-max)
L
(min-max)
(1)
1
1
124 - 125.5 mm
0 - 15 mm
149 - 151 mm
0 - 15 mm
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents