REMEHA Quinta Ace 30 Installation And User Manual page 49

High-efficiency wall-hung gas boiler
Hide thumbs Also See for Quinta Ace 30:
Table of Contents

Advertisement

Tab.41
Factory settings at advanced installer level
Code Display text
Description
AP00
Manual
Enable manual
2
Heat
heat demand
Demand
function
AP02
Setpoint
Flow temperature
6
manual HD
setpoint for manual
heat demand
AP05
Outdoor
Enable outdoor
6
sensor
sensor
AP10
Boiler Pump
Configuration of the
2
function
boiler pump as
zone pump or
system pump (feed
lowloss header)
AP11
Can line
Can line length
1
length
CP1
T.OutdoorT
Assigning the
30
oZone
outdoor sensor to
zone ...
CP2
ZoneRoom
Adjustment of the
40
UnitInfl
influence of the
zone room unit
CP2
CalSondeA
Calibration of Zone
50
mbZone
Room Unit
CP7
Zone
The zone is after a
70
Buffered
Buffer tank
DP0
Abs. max
Maximum fan
03
fan DHW
speed on Domestic
Hot Water
DP0
Calorifier Tf
Flow setpoint offset
05
offset
for loading calorifier
DP0
Hyst
Hysteresis to start
06
calorifier
heating calorifier
DP0
Postrun
Post run time of the
20
DHW
DHW pump/3 way
pump/3wv
valve after DHW
production
DP0
DhwCalorifi
Offset for calorifier
34
erOffset
sensor
DP1
DHW load
DHW load type (0 :
40
type
Combi, 1 : Solo)
GP0
Fan RPM
Maximum fan
07
Max CH
speed during
Central Heating
mode
7684359 - v.06 - 10012019
Range
Func­
tionGroup
0 = Off
Gas fired
1 = With
appliance
setpoint
2 =
TOutdoor
Control
10 °C - 90
Gas fired
°C
appliance
0 = No
Outdoor
outside
temperature
sensor
1 = AF60
2 = QAC34
0 = No
Gas fired
1 = Yes
appliance
0 = < 3m
Mandatory
1 = < 80m
bus master
2 = < 500m
0 - 4
Direct zone
0 - 10
Direct zone
-5 °C - 5 °C
Direct zone
0 = No
Direct zone
1 = Yes
1000 Rpm -
Gas fired
7000 Rpm
appliance
0 °C - 50 °C Tank DHW
2 °C - 15 °C Tank DHW
0 Sec - 99
Gas fired
Sec
appliance
0 °C - 10 °C Tank DHW
0 = Combi
Internal
1 = Solo
DHW
2 = Layered
Tank DHW
cylinder
3 = Process
heat
4 = External
1400 Rpm -
Gas fired
7000 Rpm
appliance
Navigation
30
45
Gas fired
0
0
appliance
Gas fired
40
40
appliance
Outdoor
1
1
temperature
Gas fired
0
0
appliance
Mandatory
0
0
bus master
Direct zone
0
0
Direct zone
3
3
Direct zone
0
0
Direct zone
0
0
Gas fired
4100 5400 5100 5600 6300 6700
appliance
Tank DHW
20
20
Tank DHW
5
5
Gas fired
10
10
appliance
Tank DHW
2
2
Internal
1
1
DHW
Tank DHW
Gas fired
appliance
Gas fired
4100 5400 5100 5600 6300 6800
appliance
8 Settings
55
65
90
115
0
0
0
0
40
40
40
40
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
3
3
3
3
0
0
0
0
0
0
0
0
20
20
20
20
5
5
5
5
10
10
10
10
2
2
2
2
1
1
1
1
49