Status Displays - Siemens Simatic IPC547E Operating Instructions Manual

Hide thumbs Also See for Simatic IPC547E:
Table of Contents

Advertisement

Overview

1.5 Status displays

1.5
Status displays
Front status displays
The status displays integrated in the front door provide information on the status of the
device components listed in the following table.
Item
Status
Meaning
display
POWER
Operating mode of the PC
HDD
Access to hard disk
TEMP
Temperature status
FAN
Fan status
HDD0 Alarm
HDD alarm in connection
with RAID and monitoring
HDD1 Alarm
software
HDD2 Alarm
HDD3 Alarm
20
LED
Description
OFF
Hibernate, switched off or disconnected from
the mains
GREEN flashing
Windows is in Standby mode
GREEN
PC in operation
OFF
No access
GREEN
Access
OFF
No error
RED flashing
Possible causes:
OFF
No error
RED flashing
Possible causes:
OFF
RAID is OK
A RED LED is lit up
The associated drive is not OK
All RED LEDs are
RAID synchronized
flashing
All RED LEDs are lit
RAID is not OK
up
The faulty drive could not be localized by the
monitoring software. It may be possible to
detect the defective drive with the RAID
software, see chapter "RAID1 system
(Page 51)", "RAID5 system (Page 52)" or
"RAID system with hot spare drive
(Page 52)".
CPU temperature is critical
Device temperature is critical
CPU heat sink fan fault
Enclosure fan fault
Power supply fan fault
Operating Instructions, 02/2014, A5E32317120-AB
SIMATIC IPC547E

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents