2.1 LOCAL FEED THROUGH

Agility remotes which are equipped with dual IP network ports can be configured to support a local link to a host PC in addition to
the main link to the network. The locally linked PC remains completely isolated from the main network.
To configure this arrangement, ensure that the IP port that is used for the local link is not allocated an IP address.
Note: For the local feed through feature to operate, the iPATH server must be at version 4.8 or greater while the endpoints must be
at version 4.6 or greater.
A g i l i t y H i g h - P e r f o r m a n c e K V M
i P A T H
C O N T R O L L E R
Gigabit
Ethernet
ADMIN
1.877.877.2269
BLACKBOX.COM
In operation, the user of the console at the Agility
remote can use the following hotkey combination
to toggle between the network and local links:
To change from a network link to the local link:
enter CTRL+ALT+L
To change from the local link to a network link:
enter CTRL+ALT +C
to display the OSD and choose the required
connection.
Note: The L and C default hotkeys can be changed
within the iPATH control panel.