Siemens FM 458-1 DP Manual page 75

Function blocks
Hide thumbs Also See for FM 458-1 DP:
Table of Contents

Advertisement

SIMOLINK drive coupling
I/O
Hardware address SLB (name of the SLB module), which can be
TAD
configured in HWConfig
ASL
Address of the slave for dataexchange,
value range 1 . . . 200
(initialization connection)
Number of channels for the setpoint to be sent,
NSV
value range 0. . . 8
(initialization connection)
NAV
Number of channels for the actual values to be received,
value range 0 . . . 8
(initialization connection)
XS0
Setpoint XS for channel 0 to 7,
A maximum of 8 setpoints can be sent.
to
XS7
YS0
Actual values YS from channel 0 to 7,
A maximum of 8 actual values can be received.
to
YS7
SEQ
Sequence number
Number of the blocks in the SIMOLINK block sequence
This value provides information as to whether the block was
correctly initialized.
Error status of the block
YF
YF=0
no error, YF > 0
QF
Group error bit
QF=0
no error, QF=1 for error (if YF≠0)
Configuringdata
5-18
Computation time [µs]
Can be inserted online
Can be configured in
Executed in
Special features
FM458 / PM6
34,7
no
Interrupt tasks
Cyclic tasks
Initialization mode
Normal mode
-
(default: 1)
(default: 0)
(default: 0)
(default: 0)
(default: 0)
(default: 0)
(default: 0)
(default: 0)