SIMOLINK drive coupling
10
Cyclic-automatic-mode 10
The cyclic-automatic-mode 10 offers the advantage to place the function block configuration in
cyklic tasks, in opposed to mode 3.
Processing time of the
SIMOLINK blocks
NOTE
interrupt task
settings
Interrupt source to be set for the interrupt task Ix of the SIMOLINK blocks, if:
Operating
first SLB module at
mode
0
LE bus interrupt 1
2
LE bus interrupt 5
3
LE bus interrupt 1
4
LE bus interrupt 1
NOTE
5-4
SYNC Telegram
NOP
cycle
Processing time of the
SIMOLINK blocks
cyclic Task Tx
It is necessary to set interrupt task sources for operating modes
0, 2, 3, 4 and 10, in order to initiate the configured interrupt tasks.
The settings must be made in the HWConfig in the properties
window under the "Interrupt tasks" tab. They are dependent on
the configured hardware components.
first SLB module at
slot 1
slot 2
LE bus interrupt 3
LE bus interrupt 6
LE bus interrupt 3
LE bus interrupt 3
The first SLB module can be an EXM 448-1- or an ITSL module
without optional SLB. The settings for the second SLB module
are only relevant for an ITSL module with optional SLB.
SYNC Telegram
cycle
Processing time of the
SIMOLINK blocks
second SLB
module at slot 1
LE bus interrupt 2
LE bus interrupt 7
LE bus interrupt 2
LE bus interrupt 2
Function Blocks - FM 458-1 DP
cycle
second SLB
module at slot 2
LE bus interrupt 4
LE bus interrupt 8
LE bus interrupt 4
LE bus interrupt 4
Edition 12.2004