Slsv2, Slsv2R Simolink Send Block For 2 Setpoints - Siemens FM 458-1 DP Manual

Function blocks
Hide thumbs Also See for FM 458-1 DP:
Table of Contents

Advertisement

5.6

SLSV2, SLSV2R SIMOLINK send block for 2 setpoints

Symbol
Hardware addresse SLB ―GV
Address of the first slave ―I
No. of slaves ―I
Axix cycle length ―DI
Channel number for setpoint 2 ―I
Channel number for the setpoint ―I
Common setpoint of the main angle ―DI
Setpoint offset for slave 0 ―DI
Setpoint offset for slave 1 ―DI
Setpoint offset for slave 2 ―DI
Setpoint offset for slave 3 ―DI
Setpoint offset for slave 4 ―DI
Setpoint offset for slave 5 ―DI
Setpoint offset for slave 6 ―DI
Setpoint offset for slave 7 ―DI
Brief description
Mode of operation
Function Blocks - FM 458-1 DP
Edition 12.2004
SLSV2
FSL
NSL
ACL
CTV
CSV
XSA
XO0
XO1
XO2
XO3
XO4
XO5
XO5
XO6
XO7
2 setpoints can be sent to each slave using the SLSV2 send block. In this
case, the block can handle a maximum of 8 slaves. The first setpoint is
transferred to all of the 8 slaves.
This functionality can be used to implement a virtual shaft, especially if
the time and the position/angular setpoint must be transferred to the
slaves.
The SLSV2 and SLSV2R function blocks are functionally identical. The
only difference is the data type of the setpoint connections XO0 to XO7:
SLSV2:
SLSV2R:
1. The SLSV2 send block executes the following steps while the system
is being initialized:
− Checks the task assignment
− Initializes the task list of the SLB module corresponding to the data
configured at the inputs
2. In the normal system mode ("RUN" mode), the SLSV2 send block
executes the following steps:
− Calculates the setpoints
− Checks that the inputs are within the permissible value ranges
− Enters the setpoints to be sent into the write buffer of the SLB
module
SIMOLINK drive coupling
SEQ
I ― Sequence number
YF
I ― Block group error status
QF
BO ― Group error bit
DINT
REAL
5-15