The same occurs with the sectors when more than 8
are activated at a time.
In the lower one it shows the outputs activated,
starting by the pumps (M1234), fertilizers (F12345678
LF), mixers (A12345678) and the filters.
P01 03
S05 06 07 24 33
M1
F124 A12
The third screen indicates the digital functions
activated, whenever they have been configured. The
first ones to be shown at the first line are the irrigation
counters ones (IC1234), the fertilizers counters
(FC12345678), the stop functions (Stop:1234), the
program start ones (Start:12345678) and at the sec-
ond line, the general malfunction function (Gen. Fai.),
the filters differential pressure gauges (Pre. Dif. 1234),
the intrusion alarm one (Alarm) and the diesel detector
one (D. Diesel).
IC1 3
FC
Stop: 3
Av. Gen. Pre. Dif. 2
If volumetric counters for the irrigation or fertiliza-
tion are set in the installation, it will be explained on
the fourth screen of the instantaneous flows.
In the first line it shows the irrigation flows. Be-
sides this, if flow control is ordered it can show the
">" of major or the "<" of minor after the irrigation
counter number, when the instantaneous flow is going
out of the margins. The maximum value that can be
displayed on screen in each format is 650.00 or
6500.0 m
3
/h
The second line is for the fertilizers instantaneous
flow. When more than four are configured, they will be
shown intermittently in two groups. The maximum
value that can be displayed on screen is 650.00 or
6500.0 L/h
1=034.40 2<012.77 3=000.00 m
F1=000.00 F2=033.21 L/h
When filters cleaning group has been configured,
it will show a screen per group with the information of
the filter which is doing the cleaning and the irrigation
3
units (minutes or m
) missing for the following clean-
ing.
Filters G1, Cleaning the 02 (045")
Units between cleanings: 0262
If a pressure or pH regulation option is installed,
we will see in the first line of the screen the instanta-
neous value of the pH sensor, at its right the reference
requested for the irrigation that is taking place at that
moment, in brackets the injection percentage and
finally, the conductivity sensor value (EC).
In the second line the values correspondent to
Filter: 00
Start: 2 7
Alarm
3
/h
the pressure regulation, with the pressure sensor
value, the reference and the injection %.
06.8 pH
Ref. = 06.7 pH
03.5 bars
Ref. = 03.5 bars
On the last view screen, it informs about which
elements extern to the controller there is communica-
tion established with.
Communications:
PC-yes
Microisis-yes
METOS-yes

12.2. PROGRAMS VIEW

For each one of the 40 programs, there is an in-
formative screen of the program condition. If it is irri-
gating it will show in the first line next to the program
number the number of the sub-program that is pro-
ceeding, next, if some determiners are set for the pro-
gram it will be shown by the following texts:
o Non active time
o Non active period
o Non active day
o Conditional stop
o Stop by priority
o Stop by filter cleaning
o Stop by filters overlap
o Waiting for the starting to end
o OUT OF SERVICE
When the irrigation is ordered by pressing at sev-
eral activations, it will show the left ones and the time
missing for the next one:
o Activations: 03
Later, if there is a pre-irrigation proceeding in that
moment, it will inform of the units missing to reinitiate
the fertilization.
In the second line, when irrigating, there will be
the units of irrigation and fertilizer still missing to be
applied.
P01-08
I= 02:18
F1=00:35 F2=01:05
The irrigation units format can vary depending on
the following list:
o Hours and minutes, 00:00
o Minutes and seconds, 00'00"
o Volume in cubic meters , 0000 m3
o Volume in liters, 0000 L
The fertilizer units one is:
o Hours and minutes, 00:00
o Minutes and seconds, 00'00"
o Volume in liters, 0000 L
o Volume in deciliters, 0000 dl
o Volume in centiliters, 0000 cl
(045%)
02.1 mS
(075%)
SMS-yes
RADIO-no
MONOCABLE-yes
01:20
Pre.= 00:05