Installer's Configuration - Progres AGRONIC 4000 Instruction Manual

Version 2 at 220 vac or 115 vac
Hide thumbs Also See for AGRONIC 4000:
Table of Contents

Advertisement

Examples:
00000008: digital input 8 of the Base
01000402: digital input 2 of the Expansion module 4 (ME4)
08101502: digital input 2 of the Agrónic Radio 868-16, Agrónic Radio module 15 (MAR15)
09102301: digital input 1 of the Agrónic Radio 2.4, Agrónic Radio module 23 (MAR023)
07109007: digital input 7 of the Agrónic Monocable 120, Agrónic Monocable module 90 (MAM90)
4.6.3. Analog inputs (sensors)
Device
00: Base
01: Expansion modules
02: Agrónic Radio 868 modules
04: SMS Messages
05: MicroIsis
06: Metos
07: Agrónic Monocable 120 modules
08: Agrónic Radio 868-16 modules
09: Agrónic Radio 2,4 modules
Examples:
00000003: analog input 3 of the Base
01001601: analog input 1 of the Expansion module 16 (ME16)
04000003: input of SMS message 3
05000203: analog input 3 of the MicroIsis 2
07101001: analog input 1 of the Agrónic Monocable 120, Monocable module 10 (MAM10)

4.7. INSTALLER'S CONFIGURATION

Upon entering in this section the following menu
is displayed:
Erasure : 1
Test : 2
Options : 4
Alarms : 5
Erasure
Erasure: Carry out a total erasure.
Carry out an erasure of the record.
Test
Carry out a test of relays.
Test of Analog outputs (0-10 V.)
Test of the serial ports.
Value of digital adjustment of the clock, nor-
mally there is "210" for an average tempera-
ture of 25 °C. If the average temperature was
higher the value should be lowered.
Various:
Choose whether to operate the volume in met-
ric units (m
3
) or in U.S.A. units (Gallons).
Increase the format of the instantaneous vol-
ume for irrigation and fertilizing meters, going
from 650.00 m
2
The minutes for control of error in watering or
fertilizer counters; by default there are 10 min-
utes.
When a watering program is outside of the
schedule or active period and has pending ac-
0
0
1
0
0
0
1
1
1
Various: 3
Comunic. : 6
o liters per hour to 6500,0.
Module
000
001 to 016
001 to 032
000
001 to 004
000
001 to 120
001 to 064
001 to 120
tivations to be completed, it must be config-
ured if it is to be cancelled or continued.
When a program comes out of its active time-
table, the watering in progress may be can-
celled.
To be able to keep the motors on when there
is a conditional stop by digital or analog sen-
sor.
In the pH regulation option, choose the regu-
lar by output pressed or analog 0-10 volts.
Fertilization may be stopped on cleaning the
filters.
In parallel and proportional fertilization, the
pulses that occur as the proportion ends may
be counted (useful when the time between
pulses is less than two seconds).
Options:
Activation or deactivation of options once the
equipment is installed, to activate enter the
code supplied by PROGRÉS and to deactivate
enter an incorrect code.
Alarms:
Activation of alarms and/or SMS messages for
each of the anomalies.
Communications:
Agr.Rad868 : 1
Agr.Rad24 : 2
ModBus : 4
Others : 5
13
Input
01 to 04
01 to 02
01 to 02
01 to 08
01 to 08
01 to 24
01
01 to 02
01 to 02
Agr.Mon. : 3