be entered in the sensor, meaning it is the digital func-
tion of the rain gauge.
P01 Determiner 4, type : 07
Sensor: 01
Min.: 0200 Wm
The "calculation reference" is used to define an
integration point of reference above which the value
modification factor which surpasses the reference will
be applied.
P01 Determiner 4, Type : 07
Calculation reference : 02000 Wh/m
At the irrigation program, next to the manual fac-
tor and pressing the "mode" key, the integration value
since the previous irrigation will be asked.
Example:
The irrigation units can be increased by solar ra-
diation, temperature, etc., or diminished by rain, etc.
Type 10 and 11 determiners: Having the option
installed the irrigation and fertilizer units and can be
modified in relation to the reading of a sensor
(evapotranspiration, soil moisture, etc.).
The number of the "sensor" and the crop con-
stant have to be entered. The units that have to be
used are millimeters per day.
P01 Determiner 4, type : 10
Sensor : 32
Crop Constant : 0.93
2
Lim.: 12500 Wh/m
2
2
The "reference for calculation" is used to define a
point of reference in the units of the sensor above
which will be applied the modification factor in ratio to
the value that surpasses the reference, when it is a
positive value, when negative it will be applied upon
going lower than the reference.
P01 Determiner 4, type : 10
Reference for calculation : + 0.80 mm/d
In the irrigation program, next to the manual fac-
tor, pressing the "mode" button will ask for the modifi-
cation factor. In an evapotranspiration sensor the
"crop constant" is used; in other types of sensors
leave the value at 1.00.
Etc = Eto * Kc
Etc = Evapotranspiration of crop
Eto = Evapotranspiration
Kc = Crop constant

6.8. COMMUNICATION PARAMETERS

This section indicates which external elements
will be communicated by the equipment. These ele-
ments may be:
PC program
-
SMS messages sending and recep-
-
tion (GSM only)
Agrónic Radio 868
-
Agrónic Radio 2,4
-
Agrónic Monocable
-
Expansion modules
-
Microisis
-
µMetos
-
COMMUNICATION PC : 1
Agr.Rad868: 4
Agr.Rad24 : 5
COMMUNICATION
uMetos : 8
It is important to stand out that all the communi-
cations are normally non installed options at the base
unit. When this takes place the "-non installed option-"
message will appear on the screen.
6.8.1. Communication with PC program
When linking a PC to several Agrónic 4000 each
one of them have to be numbered in order to differen-
tiate them in the net. Enter the value at "Agrónic Num-
ber".
Communication with the PC:
Agrónic number : 01
SMS : 2
GSM : 3
Agr.Mon. : 6
Mod.Exp. :7
MicroIsis : 8