If a "in series" and "proportional" application is
programmed, the proportion is configured in parame-
ters of fertilizers for each one of them, but, if the ap-
plication is "parallel" and "proportional" it is pro-
grammed in each one of the sub-programs, as can be
seen in the last line of this example screen:
3
I0185 m
F1 10/03 F2 08/13
According to this, each fertilizer has two values,
an irrigation units one at the left of the bar, and a fertil-
izer one at the right of it.
If operation at both values by volume, the previ-
ous example would be: per each 10 m
liters, deciliters or centiliters of "fertilizer 1", and for the
second 13 liters, deciliters or centiliters of "fertilizer 2"
per each 8 m
3
of water. At "flow-parameters" the units
these proportions will be used with are identified.
The irrigation units of the ratio are in time or vol-
ume, always depending on the irrigation units config-
ured in "Parameters - Volumes" [6.5.]. The irrigation
units can be modified with the key "T/V" for each pro-
gram. This way, combinations may be used, for ex-
ample irrigation for 2 hours and injection 3 liters of
fertilizer per 10 m
3
of irrigation.
I02:00
F1 10/03 F2 08/13
In this way of operation a total value of fertilizer to
be applied is not given but it is continuously relates to
the irrigation quantity programmed.
Another possibility is by using the arrows from here or
from the different values of the sub-program; use the
up arrow to increase and the down one to decrease.
The right-left arrow keys are used to move the
cursor between the different values.
To exit any programs screen, press the "Func-
tion" or "View" keys.
3
of water, 3
To move to another pro-
gram the cursor has to be
placed at the program number
(P01) and enter the new one
by using the up arrow key to
increase and the down one to
decrease.
In order to accede to a
sub-program the cursor has to
be placed at the (P01-00)
value and enter the new one.
8. READINGS
The READINGS function will be used whenever
we want to consult statistical data. To do so, press the
"FUN" key, choose the function by its number (2) and
then press "Enter".
Programs : 1
Readings : 2
Parameters: 4
Manual
The "Readings" menu is the following:
READINGS
Totals: 1
New anomalies : 3
History: 4
READINGS
Agr. Radio 868: 6 Agr.Rad24 :7
Ag.Monocable : 8
In order to exit any reading screen press the
"Function" or "View" keys.
8.1. TOTALS READINGS
At the "Totals" the water and fertilizers units ap-
plied by time and volume are shown, in general and in
each sector.
The first screen of "General totals" informs of the
date and time when the last erasure of totals was car-
ried out, the time and total volume of irrigation and the
time or total volume of each fertilizer.
General totals
15/07/02
Irrigation =
0000:00.00
General totals
F2 000000.00 L F3 000000.00 L F4 000000.00 L
General totals
F6 0000:00.00
F7 0000:00.00
All the other totals screens correspond to the val-
ues of the 99 sectors which can be found in the
Agrónic 4000.
Sector totals 01
Irrigation =
0000:00.00
Sector totals 01
F2 000000.00 L F3 000000.00 L F4 000000.00 L
Sector totals 01
F6 0000:00.00
F7 0000:00.00
Erasure : 3
: 5
Clock
Anomalies : 2
Sensors : 5
17:47.11
000000.000 m3
F1 000000.00 L
F5 0000:00.00
F8 0000:00.00
000.00 m3/h
000000.000 m3
F1 000000.00 L
F5 0000:00.00
F8 0000:00.00
33