filters cleaning will temporary stop. Once finished, the
sectors will continue at the same point where they
stopped.
In order to avoid a continued filter cleaning, a
maximum number of cleanings can be configured.
When the programmed value is surpassed it enters in
the "Filter cleaning without control" malfunction. In
order to reactivate the cleaning go to the "manual"
function, "malfunctions" sector and stop it.
In order to count a cleaning as a continued one,
the time between one cleaning and another must be
of 5 minutes.
In order to avoid the control, leave the value at 0.
Stop sectors when cleaning : YES
Max. Num. of cleanings in a row : 3
At the following screen, the pumps and volume
counters are assigned to the filters group. With this the
next features are reached:
Count the time between cleanings when
pumps irrigating and coinciding with the as-
signed in this sector, whenever at flow pa-
rameters the irrigation had been configured in
units of time.
Count the volume between cleanings when
pulses of the volume counters coinciding with
the assigned here arrive, whenever at flow pa-
rameters the irrigation had been configured in
units of volume.
Start the pumps configured here when the
stop of the irrigation sectors in the filters
cleaning has been ordered.
Take into account the differential pressure
gauge correspondent to the group of filters,
whenever that any pump of the ones assigned
here is set on.
In relation to P 1 2 3 4
Y Y N N
6.3. GENERAL OUTPUTS PARAMETERS
The general outputs necessary for the correct
working of the installation are configured in this sector.
Each function (pump, fertilizer, mixer, filter, etc.)
is assigned an output relay. This can be placed at the
base of the unit or in distance external modules by
cable or radio. Section 4.6.1 specifies how the eight
digits of the outputs are coded.
The Agrónic 4000 can control 4 independent irri-
gation pumps which will automatically start or stop if
irrigation sectors are set on and have the pump as-
signed.
An output relay has to be assigned to each
pump. In case of avoiding the use, leave the value at
0.
The start temporization corresponds to the time
the activation of the relay will be delayed since the
C 1 2 3 4
Y Y N N
start is ordered. If the value is set at 0, the output acti-
vation is immediate.
The stop temporization keeps the output acti-
vated as long as programmed here when the order of
stop arrives. At 0, the deactivation is immediate.
Pump 1
Nº of output : 00000024
Temporisation on/off : 022" / 005"
The following four screens will be used to assign
output relays to the fertilizers and mixers set in the
installation. The ones which are not going to be used
will be left at 0.
In case of a common mixing to all the fertilizers,
the same output relay has to be assigned to all the
configured mixers.
Fertilizers
Nº of output :
00000020
Fertilizers
Nº of output :
00000000
Fertilizers
Nº of output :
00000000
Fertilizers
Nº of output :
00000000
Mixers
Nº of output :
00000017
Mixers
Nº of output :
00000000
Mixers
Nº of output :
00000000
Mixers
F7
Nº of output :
00000000
If necessary a fertilizer general output can be
configured so that whenever one is activated, the
general one is activated too.
F1
F2
00000019
F3
F4
00000000
F5
F6
00000000
F7
F8
00000000
F1
F2
00000016
F3
F4
00000000
F5
F6
00000000
F8
00000000