5. TECHNICAL CHARACTERISTICS

Power supply
Tension
Frequency
Energy consumption
Fuses
Input
Output
Keeping the memory which can be erased
when there is a power cut
Outputs
Digital
Analog
(option)
Inputs
Digital
Analog
(option)
Atmosphere
Temperature
Humidity
Height
Pollution
Memory backup
DECLARATION OF CONFORMITY
It follows the 89/336/CEE guidelines for the Electromagnetic Compatibility and the
73/23/CEE guidelines of Low tension for the fulfillment of the product security. The fulfill-
ment of the following specifications was demonstrated as indicated in the Official Diary of
the European Communities:
Emissions EN 50081-1:94
Immunity EN 50082-1:97
Harmonics
Fluctuations
Low tension guidelines:
Symbols which may appear
in the product
This symbol indicates that the electrical and electronic equipment should not be disposed of as gen-
eral household waste at its end-of-life. Instead, the product should be handed over to the applicable
collection point for the recycling of electrical and electronic equipment for proper treatment, recovery
and recycling in accordance with your national legislation.
230 Vac or 115 Vac+5% -10% CAT II
50-60 Hz
Below to 43 VA
0,800 A, T type, 250 V (slow)
6,3 A, F type, 250 V (fast)
Lithium Battery, at 3 V.
Number
16 extensible to 24, 32, 48, 64, 80, 96.
Type
By relay contact, with potential of 24 VAC (External transformer)
Limits
30VAC / 30VDC, 1 Amp, 50-60 Hz, CAT II
Number
2
Type
By voltage of 0 to 10 volts.
All outputs have double isolation in reference to the net input.
Number
12
Type
Optolinked, work at 24 VAC
Number
4
Type
4-20 mA, 0-5 V.(with galvanic separation)
0ºC to 45ºC
<85%
2000m
Grade 2
Clock and data
EN 55022:1994 Type B Radiated and conducted emissions.
EN 61000-4-2 (95)
EN 61000-4-3 (96)
EN 61000-4-4 (95)
EN 61000-4-5 (95)
EN 61000-4-6 (96)
EN 61000-4-11 (94)
EN 61000-3-2 (95)
EN 61000-3-3 (95)
EN 61010-1
Protection earth
terminal
Weight
Box model
(Kg.)
From 3.2 to 6.3
Above to 5 years.
Immunity to electrostatic discharges.
Immunity to the electromagnetic field of radioelectric fre-
quency.
Immunity to fast transitional in gusts.
Immunity to crash waves.
Current injection
Variations to the power supply.
Current harmonics.
Tension fluctuations (Flickers).
Security requirements of measurement electric units, con-
trol and use in laboratory.
Danger, risk of
electroshock
15
Built-in model
From 4.0 to 5.0
Box terminal