20
Code 11: Irrigation counter 1, pulses
Code 12: Irrigation counter 2, pulses
Code 13: Irrigation counter 3, pulses
Code 14: Irrigation counter 4, pulses
-Pulse value: 01000 L
-Maximum time between pulses: 240"
Code 15: Fertilizer counter 1, pulses
Code 16: Fertilizer counter 2, pulses
Code 17: Fertilizer counter 3, pulses
Code 18: Fertilizer counter 4, pulses
Code 19: Fertilizer counter 5, pulses
Code 20: Fertilizer counter 6, pulses
Code 21: Fertilizer counter 7, pulses
Code 22: Fertilizer counter 8, pulses
-Pulse value: 0100 cl
-Maximum time between pulses: 200"
Code 23: Irrigation counter 1, frequency
Code 24: Irrigation counter 2, frequency
Code 25: Irrigation counter 3, frequency
Code 26: Irrigation counter 4, frequency
-Cycles per litre: 009.43 Hz
Code 27: Fertilizer counter 1, frequency
Code 28: Fertilizer counter 2, frequency
Code 29: Fertilizer counter 3, frequency
Code 30: Fertilizer counter 4, frequency
Code 31: Fertilizer counter 5, frequency
Code 32: Fertilizer counter 6, frequency
Code 33: Fertilizer counter 7, frequency
Code 34: Fertilizer counter 8, frequency
-Cycles per centiliter: 128.50 Hz
Code 35: Rain gauge
-Liters per pulse: 00.5 L/m
Code 36: Start 1 of programs
Code 37: Start 2 of programs
Code 38: Start 3 of programs
Code 39: Start 4 of programs
Code 40: Start 5 of programs
Code 41: Start 6 of programs
Code 42: Start 7 of programs
Code 43: Start 8 of programs
-Detection delay: 030"
-Stop Y/N : NO
[ values for DIESEL Control option ]
Once the function has been entered, the number
of input has to be chosen, to do so, take into account
the chart of the section 4.6.2.
Sector 4.3.3 has to be taken into account to deal
with the installation and the connection.
For most of the inputs there is a common value
which is the "Detection delay". This temporization
guarantees the time the input has to keep connected
to carry out its function.
The "General malfunction" function is used to
stop completely the unit due to the connection of a
security element. It is necessary to have any pump
general output operation in order to have the chance
of acting.
has been repaired, the "Manual Function" has to be
used in order to finish it and continue with the irriga-
tion proceeding at that moment at the same point
where it stopped.
can start the cleaning by connecting a "Differential
pressure gauge", which measures the difference of
pressure between the input and output of the filters.
When the power is switched on and the irrigation is
working, after the "detection delay" temporization, it
will clean the filters.
eration can be configured in three different ways, be-
sides this, the stop inputs that each irrigation sector
has to use are configured at the "Sector parameters"
sector.
the sector or group of sectors in order to go to the
following sub-program. If the program is reinitiated, it
will try to irrigate the sectors were previously affected
by the input.
group of sectors is stopped and adjourned as long as
the input is connected. Once the input is discon-
nected, the irrigation will continue at the same point
where it stopped.
input will stop operation definitively. Enter at the
2
"Function-Manual-Malfunctions" to end the stop.
rigating and a "Stop" input is activated, all the group
will stop irrigating, even though not all of them are
assigned to the input.
from vandalism the installation. To do so, connect the
protection elements such as radars, door sensors, etc.
in series with the normally closed contacts, to the in-
put; the first one that opens, after the detection delay
temporization, will activate the alarm output and, if the
SMS messages option is installed, will send a text
message to a mobile phone (SMS messages sending
option).
11 to 14, can work with pulses transmitter from 1 to
10.000 liters.
the time between two pulses with the lowest operation
flow at the "Maximum time between pulses". This de-
tects the fact that there is no irrigation flow. As an ex-
ample, we will calculate the time for a flow of 2 m
and a counter of 100 liters:
When a malfunction has taken place and then it
Each one of the four filter group the unit allows
For the 06 to 09 "Stop" functions, the input op-
The "Temporary" one will cancel the irrigation of
With "Conditional" the irrigation of the sector or
At the "Definitive", all the sectors assigned to the
If in an irrigation program, a group of sectors is ir-
The "Intrusion alarm" function is used to protect
The four possible irrigation counters, functions
It is necessary to enter the value in seconds of
2.000 L/h ÷ 3600 = 0,5555 L/sec.
100 ÷ 0,5555 = 180 seconds.