Progres AGRONIC 4000 Instruction Manual page 28

Version 2 at 220 vac or 115 vac
Hide thumbs Also See for AGRONIC 4000:
Table of Contents

Advertisement

28
6.8.4. GSM modem checking
When entering at the "GSM" section, the cover
level of the telephone signal which is being received,
the condition of the PIN card and if GSM telephone
network (operator where the PIN is contracted) is
available is shown.
GSM modem checking :
Look at coverage? YES
The coverage is correct based on a level of 17.99.
GSM modem checking:
Look at PIN condition?: YES
GSM modem checking:
Look if net. Available?: YES
6.8.5. Communication with Agrónic Radio 868
This indicates if communication with the Agrónic
Radio is activated or not.
Agrónic Radio communication :
For each of the radio modules it must be speci-
fied if communication with it is desired or not.
Agrónic Radio communication:
Communicate with module 01 : YES
If the model is Agrónic Radio 868 these configu-
ration parameters must be entered in the modules.
Agrónic Radio communication:
Enter to module 01 configuration : YES
When entering at the configuration the following
questions will be asked:
"Action due to communication error (0-1-2): 0", at
-
"0" it maintains the status of the electrovalves, at
"1" it closes them immediately, at "2" it closes
them after being 10 minutes without having a cor-
rect communication.
"Potency level (0 a 7): 4", it is used to fix the emis-
-
sion potency level.
"Minutes between sensors readings: 000'", it will
-
be the cadence with which the readings of the
elements connected to the Analog inputs of the
modules will take place. Leave it at 000' to avoid
the readings.
Activate : YES
"Sensors power supply x10 ms: 000", it is the
-
time, in units of 10 milliseconds the sensors power
supply will last before doing the reading and deac-
tivate them. It will be used to establish the signal
according to the type of sensor.
"Blast power greater than 12 VDC : NO", to acti-
-
vate solenoid impulse latch to 12 Volts, reply "NO"
and to give the blast greater tension, reply "YES".
"It is a translation module: YES", in order that a
-
module can deal with translator functions, "YES"
has to be entered and then assign each module of
which it is a translator.
"3 wires output latch", to connect solenoid im-
-
pulse latch in 3-wires radio mode enter "YES" and
for two way "NO".
"Is MR of level 2?: YES", will show YES whenever
-
the MR it at a level of 2 (after the first relay).
"Start configuration sending" it is used to update a
-
module configuration when answering "YES". It is
necessary that the module to be configured has
the bridge installed to indicate it that it will receive
these special data. Once received the new values
the pilot light will switch off at the module. Then
confirm the question "Finish configuration send-
ing". For further details look at radio modules
characteristics sheet.
6.8.6. Communication with Agrónic Radio 2,4
This indicates if communication with the Agrónic
Radio2,4 is activated or not.
Agronic Radio 2,4 communication :
Activate : Y.
6.8.7. Communication with Agrónic Monocable
This indicates if communication with the Agrónic
Monocable is activated or not.
Agronic Monocable communication:
Activate : Y.
If the model is the Agrónic Monocable 64 it must
be specified if communication with it is desired or not
Agronic Monocable communication: YES
Communicate with module 01 : YES
6.8.8. Communication with Expansion Modules
This indicates which Expansion Modules are con-
nected to the Agrónic.
Communication with the expansion modules :
Communicate with module 01? YES

Advertisement

Table of Contents
loading