The settings can be entered using the inverter control panel. Refer to the inverter ope-
rating instructions for more information.
Switch on the voltage supply for the UFI11A and all connected inverters.
Set an individual SBus address (P813) on the inverters. Recommendation: Assign
the addresses starting from address 1 and working in ascending order according to
the arrangement of inverters in the switch cabinet. Do not assign address 0 since this
is used by the UFI11A.
Check the SBus baud rate (P816, factory setting = 500 kbaud).
Set the Setpoint source (P100) to SBus (value 10).
Set the Control signal source (P101) to SBus (value 3).
Set the terminal assignment of the binary inputs. The value 0 is recommended for
®
P60- in MOVITRAC
–DI01 CW/STOP
–DI02 CCW/STOP
–DI03 FIX SETPT SW.OV(not connected)
–DI04 n11/n21
–DI05 n12/n22
–Program the unused terminals to "NO FUNCTION" if you are using a MOVIDRIVE
or MOVIDRIVE compact.
Important: If you need to set P815 SBus timeout delay for MOVITRAC
only possible using a PC. The default value is 0, which means timeout monitoring is
switched off. Set P815 to the value 1 s.
Switch on the Autosetup function using the DIP switch on the UFI11A. The function is
active for as long as the SYS-FLT LED is flashing briefly with a long interval between
flashes. The LED stays off after the scanning process if at least one inverter has been
detected. The Autosetup DIP switch must stay switched on. Autosetup can be reactiva-
ted by switching the DIP switch off and on again. The SYS-FLT LED remains on follo-
wing Autosetup if no inverter is detected. In this case, check the cabling of the SBus, the
terminating resistors of the SBus, the voltage supply to the inverters and the SBus
address settings (P813).
07. This corresponds to the following assignment:
(applied to 24 V, enable CW direction of rotation)
(applied to 24 V, enable CCW direction of rotation)
(not connected)
(not connected)
Manual – Fieldbus Interface INTERBUS UFI11A
®
®
07, this is

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the INTERBUS UFI11A and is the answer not in the manual?

Table of Contents