Datavideo TLM-170V Instruction Manual page 33

17.3” scopeview production monitor
Hide thumbs Also See for TLM-170V:
Table of Contents

Advertisement

Adjust the monitor's backlight value and click the Update button in the Luminance Units pane
located at the top right of the window above.
As soon as the Update button is clicked, the Calibration Status window will appear along with the
Calibration Area and a dialogue box. Drag the Calibration Area onto the TLM-170V. Finally point
the probe at the calibration area as close as possible then click the OK button in the dialogue box
to start calibration. Repeat the process until the MAX value in the Luminance Units pane is in the
range of 80 – 120. Note that the closer the MAX value to 100, the better the TLM-170V is
calibrated.