Contents Safety instructions ..................4 General safety instructions .........4 Recommendations ..........5 Liabilities ...............6 1.3.1 Manufacturer’s liability ..........6 1.3.2 Installer’s liability .............7 1.3.3 User’s liability ............7 About this manual ..................8 Symbols used ............8 2.1.1 Symbols used in the manual ........8 2.1.2 Symbols used on the equipment ......8 Abbreviations ............9 Technical specifications ................10 Certifications ............10...
Page 3
Contents 5.3.5 Setting the time and date ........23 5.3.6 Selecting a timer programme ........24 5.3.7 Customising a timer programme ......24 Installation shutdown .........26 Antifreeze protection ..........26 Checking and maintenance ..............28 General instructions ...........28 Periodic checks ..........28 Troubleshooting ..................30 Anti-hunting ............30 Messages (Code type Bxx or Mxx) ....30 Faults (Code type Lxx or Dxx) ......32 Energy savings ..................38...
AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions Safety instructions General safety instructions DANGER This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have...
1. Safety instructions AGC 10/15 AGC 15 AGC 25 AGC 35 DANGER If you smell flue gases: Switch the appliance off. Open the windows. Evacuate the premises. Call your fitter. DANGER The installation and maintenance of the boiler must be undertaken by a qualified fitter/engineer...
AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions DANGER For safety reasons, we recommended fitting smoke and CO alarms at suitable places in your home. 4 Regularly check the water pressure in the installation (minimum pressure 0.8 bar, recommended pressure between 0.8 and 1.5 bar).
1. Safety instructions AGC 10/15 AGC 15 AGC 25 AGC 35 1.3.2. Installer’s liability The installer is responsible for the installation and commissioning of the appliance. The installer must respect the following instructions: 4 Read and follow the instructions given in the manuals provided with the appliance.
AGC 10/15 AGC 15 AGC 25 AGC 35 2. About this manual About this manual Symbols used 2.1.1. Symbols used in the manual In these instructions, various danger levels are employed to draw the user’s attention to particular information. In so doing, we wish to safeguard the user’s safety, highlight hazards and guarantee correct...
2. About this manual AGC 10/15 AGC 15 AGC 25 AGC 35 Caution: danger, live parts. Disconnect the mains power prior to any operations. M002628-A Abbreviations 4 3CE: Collective conduit for sealed boiler 4 DHW: Domestic hot water 4 Interscenario switch: Home automation switch that can be used...
AGC 10/15 AGC 15 AGC 25 AGC 35 3. Technical specifications Technical specifications Certifications CE identification no CE-0085CM0178 NOx classification 5 (EN 15502-1, EN 15502-2-1) Type of connection Chimney: B Flue gas outlet: C 13(x) 33(x) 43(x) 83(x) 93(x) Technical specifications...
Page 12
3. Technical specifications AGC 10/15 AGC 15 AGC 25 AGC 35 Boiler type AGC 10/15 AGC 15 AGC 25 AGC 35 Flue gas temperature minimum- °C 30 - 65 30 - 65 30 - 80 30 - 75 maximum Maximum counter pressure...
AGC 10/15 AGC 15 AGC 25 AGC 35 4. Description Description Operating principle 4.1.1. Gas/air setting Air is sucked in by the fan and the gas injected into the venturi attached to the fan inlet. The fan rotation speed modulates and adapts to thermal energy requirements thanks to the temperatures measured by the various sensors.
4. Description AGC 10/15 AGC 15 AGC 25 AGC 35 Main parts Flue gas discharge pipe Flue gas measuring point Heat exchanger Ignition/ionization electrode Box for the control PCBs Control panel Command module Water pressure sensor Circulation pump Hydroblock 3-way valve...
AGC 10/15 AGC 15 AGC 25 AGC 35 4. Description Control panel 4.3.1. Description of the keys AUTO Temperature setting key (heating, DHW, swimming pool) Operating mode selection key DHW override key Key to access the parameters reserved for the installer...
4. Description AGC 10/15 AGC 15 AGC 25 AGC 35 4.3.2. Description of the display n Key functions Access to the various menus > Used to scroll through the menus Used to scroll through the parameters The symbol is displayed when help is available Used to display the curve of the parameter selected <...
AGC 10/15 AGC 15 AGC 25 AGC 35 4. Description n Solar (If connected) The solar load pump is running The top part of the tank is reheated to the tank set point The entire tank is reheated to the tank set point <...
4. Description AGC 10/15 AGC 15 AGC 25 AGC 35 n System pressure Pressure indicator: The symbol is displayed when a water pressure sensor is connected. Flashing symbol: The water pressure is insufficient. Steady symbol: The water pressure is sufficient.
Page 19
AGC 10/15 AGC 15 AGC 25 AGC 35 4. Description 5. To modify the parameter, turn the rotary button. 6. To confirm, press the rotary button. CURRENT PROG.C "Choice of the timeprogram applied C" To cancel, press key h .
5. Operating the appliance AGC 10/15 AGC 15 AGC 25 AGC 35 Operating the appliance Putting the appliance into operation 1. Turn on the boiler using the on/off switch. C003159-B 2. The first time the boiler is powered up, the LANGUAGE menu is displayed.
Page 21
AGC 10/15 AGC 15 AGC 25 AGC 35 5. Operating the appliance User level - #MEASURES Menu Parameter Description Unit Outside temperature °C OUTSIDE TEMP. Room temperature of circuit A °C ROOMTEMP.A Room temperature of circuit B °C ROOMTEMP.B Room temperature of circuit C °C...
5. Operating the appliance AGC 10/15 AGC 15 AGC 25 AGC 35 Changing the settings 5.3.1. Setting the set point temperatures C Menu Parameter Adjustment range Description Factory setting 5 to 30 °C Desired room temperature in comfort periods on circuit A 20 °C...
AGC 10/15 AGC 15 AGC 25 AGC 35 5. Operating the appliance MODE Menu Parameter Adjustment range Description Factory setting The comfort ranges are determined by the timer programme. AUTOMATIQUE 7/7, xx:xx Comfort mode is forced until the time indicated or all the time (7/7). Present time + 1...
5. Operating the appliance AGC 10/15 AGC 15 AGC 25 AGC 35 5.3.4. Setting the contrast and lighting on the display 1. To access user level: Press the > key. 2. Select the menu #SETTING. SUNDAY 11:45 Turn the rotary button to scroll through the menus or modify a value.
AGC 10/15 AGC 15 AGC 25 AGC 35 5. Operating the appliance 5.3.6. Selecting a timer programme 1. To access user level: Press the > key. 2. Select the menu #CHOICE TIME PROG.. SUNDAY 11:45 Turn the rotary button to scroll through the menus or modify a value.
Page 26
5. Operating the appliance AGC 10/15 AGC 15 AGC 25 AGC 35 4. To select a timer programme to be modified. 5. To select to days for which the timer programme is to be modified: Turn the rotary button to the left until you reach the day desired.
AGC 10/15 AGC 15 AGC 25 AGC 35 5. Operating the appliance User level - #TIME PROGRAM Menu Comfort periods / Filling enabled: P2 _______________ P3 _______________ P4 _______________ _______________ Monday 6:00 to 22:00 TIME PROG.B Tuesday 6:00 to 22:00...
Page 28
5. Operating the appliance AGC 10/15 AGC 15 AGC 25 AGC 35 4 If the water temperature is lower than 4°C, the boiler starts up. 4 If the water temperature is higher than 10°C, the boiler shuts down and the circulation pump continues to run for a short time.
AGC 10/15 AGC 15 AGC 25 AGC 35 6. Checking and maintenance Checking and maintenance General instructions The boiler does not require a lot of maintenance. Nevertheless, we recommend having the boiler inspected and serviced at regular intervals. 4 Maintenance and cleaning of the boiler must be carried out at least once a year by a qualified technician.
Page 30
6. Checking and maintenance AGC 10/15 AGC 15 AGC 25 AGC 35 4 Carry out a visual check for the presence of any water leaks. T001507-B 4 Open and close the radiator valves several times a year (this prevents the valves from seizing up).
AGC 10/15 AGC 15 AGC 25 AGC 35 7. Troubleshooting Troubleshooting Anti-hunting When the boiler is in Anti-short-cycle operating mode, the symbol ? flashes. 1. Press the "?" key. The message Operation assured when the restart temperature will be reached is displayed.
Page 32
7. Troubleshooting AGC 10/15 AGC 15 AGC 25 AGC 35 Code Messages Description Checking / solution The RL inlet on the PCU PCB Parameter error BL.RL OPEN terminal block is open Contact the professional who takes care of maintenance of the appliance...
AGC 10/15 AGC 15 AGC 25 AGC 35 7. Troubleshooting Code Messages Description Checking / solution The sensor on the plate Contact the professional who takes care of BL.DHW INST exchanger outlet is disconnected maintenance of the appliance or short circuited...
Page 34
7. Troubleshooting AGC 10/15 AGC 15 AGC 25 AGC 35 3. Press the ? key. Follow the instructions displayed to solve the problem. 4. Consult the meaning of the codes in the table below: SUNDAY 11:45 TEMP. : 68° PCU COM.FAIL D27 <...
Page 35
AGC 10/15 AGC 15 AGC 25 AGC 35 7. Troubleshooting Code Faults Cause Description Checking / solution of the fault The return temperature sensor is on Bad connection BACK S.FAILURE an open circuit Sensor fault Contact the professional who takes care of...
Page 36
7. Troubleshooting AGC 10/15 AGC 15 AGC 25 AGC 35 Code Faults Cause Description Checking / solution of the fault BURNER FAILURE PCU 5 burner start-up failures No ignition Contact the professional who takes care of maintenance of the appliance...
Page 37
AGC 10/15 AGC 15 AGC 25 AGC 35 7. Troubleshooting Code Faults Cause Description Checking / solution of the fault HRU/URC unit test error Bad connection TEST.HRU.FAIL External cause Parameter incorrectly set Contact the professional who takes care of maintenance of the appliance...
Page 38
7. Troubleshooting AGC 10/15 AGC 15 AGC 25 AGC 35 Code Faults Cause Description Checking / solution of the fault Storage tank sensor fault Bad connection ST.TANK S.FAIL Sensor fault Note: The hot water storage tank reheating Contact the professional who takes care of operation is no longer assured.
AGC 10/15 AGC 15 AGC 25 AGC 35 8. Energy savings Energy savings Energy-saving advice 4 Keep the room in which the boiler is installed well ventilated. 4 Do not block ventilation outlets. 4 Do not cover the radiators. Do not hang curtains in front of the radiators.
9. Warranty AGC 10/15 AGC 15 AGC 25 AGC 35 Warranty General You have just purchased one of our appliances and we thank you for the trust you have placed in our products. Please note that your appliance will provide good service for a longer period of time if it is regularly checked and maintained.
Tab.2 Product fiche for boiler space heaters Product name AGC 10/15 AGC 15 AGC 25 AGC 35 Seasonal space heating energy efficiency class (Prated or Psup) Rated heat output Seasonal space heating energy efficiency Annual energy consumption Sound power level L indoors For specific precautions on assembly, installation and mainte...
1 Specific information Package fiche - Boilers Fig.2 Package fiche for boilers indicating the space heating energy efficiency of the package Seasonal space heating energy effi ciency of boiler ‘I’ Temperature control Class I = 1%, Class II = 2%, Class III = 1.5%, Class IV = 2%, Class V = 3%, Class VI = 4%, from fi...
Page 46
(2) Prated is related to the preferential space heater or combination heater. Tab.5 Package efficiency De Dietrich - AGC AGC 10/15 AGC 15 AGC 25 AGC 35 Seasonal space heating energy efficiency of boiler Temperature control Seasonal space heating energy efficiency of package 300026080 - ErP03 - 29032016...
Page 48
Зубарев переулок, д. 15/1 +49 (0)25 72 / 9161-0 Бизнес-центр «Чайка Плаза», +49 (0)25 72 / 9161-102 офис 309 info@remeha.de +7 (495) 221-31-51 info@dedietrich.ru DE DIETRICH THERMIQUE Iberia S.L.U. DE DIETRICH SERVICE www.dedietrich-calefaccion.es www.dedietrich-heiztechnik.com Freecall 0800 / 201608 C/Salvador Espriu, 11 08908 L’HOSPITALET de LLOBREGAT...