Technical specifications

8.1

Applicability of technical specifications

Note
The following technical specifications only apply under the following conditions:
• The device is in good working order.
• The fan cover and filter pad are installed.
• The device is closed.
8.2

General technical specifications

See the note in "Applicability of technical specifications (Page 141)".
Article number
Dimensions
Weight
Supply voltage (V
)
N
Input current
SIMATIC IPC647E
Operating Instructions, 11/2018, A5E45589180-AA
6AG4112-3...-.... (for details, refer to the ordering documentation)
481.4 x 88.1 x 446.6 (W × H × D in mm)
Detailed dimensional specifications can be found in "Dimension drawing of the device
(Page 155)".
10 up to 14 kg; depending on the equipment
Single power supply: 100 V AC to 240 V AC (-15%; +10%)
Redundant power supply: 2 × 100 V AC to 240 V AC (-15%; +10%)
Single power supply:
Continuous current at 100 V: ≤ 6 A
Continuous current at 230 V: ≤ 3 A
At startup ≤ 80 A for 3.6 ms
Redundant power supply:
Continuous current at 100 V: ≤ 5 A
Continuous current at 230 V: ≤ 2.5 A
at startup ≤ 210 A for 1.65 ms for each module
Information on the dimensioning of the fuses in the higher-level plant circuits
A fuse, which is designed for a tripping current of typical 6.3 A, is integrated in the
power supply of the IPC. Pulse current are also taken into consideration by the "time
lag" type. In the case of fault, this fuse ensure the correct separation of the device
from the power supply.
It is recommended to use a fuse of at least 6.3 A for the protection of the higher-level
power supply circuit in addition to the power requirement of the additional devices
that are also supplied through this circuit. The tripping characteristic of the higher-
level protection must hereby take into consideration the starting currents of the IPC
and those of the other devices.