MEASure Subsystem

VMAX?

VMAX?
Query
:MEASure:[SOURce CHANnel<N>;]VMAX?
The VMAX query returns the absolute maximum voltage of the selected
source.
Returned Format
[:MEASure:VMAX] <value><NL>
1 through the number of channels in the oscilloscope connected as one unit
<N>
(maximum of 8 channels), otherwise the maximum number of channels is 2
maximum voltage of selected waveform
<value>
Example
OUTPUT XXX;":MEASURE:SOURCE CHAN2;VMAX?"

VMIN?

Query
:MEASure:[SOURce CHANnel<N>;]VMIN?
The VMIN query returns the absolute minimum voltage present on the
selected source.
Returned Format
[:MEASure VMIN] <value><NL>
1 through the number of channels in the oscilloscope connected as one unit
<N>
(maximum of 8 channels), otherwise the maximum number of channels is 2
minimum voltage of selected waveform
<value>
Example
OUTPUT XXX;":MEASURE:SOURCE CHAN1;VMIN?"