YINCrement?
Query
:WAVeform:[SOURce CHANnel<N>;]YINCrement?
The YINCrement query returns the Y-increment value currently in the
preamble. This value is the voltage difference between consecutive data
values.
Returned Format
[:WAVeform:YINCrement]<value><NL>
1 through the number of channels in the oscilloscope connected as one unit
<N>
(maximum of 8 channels)
Y-increment value in preamble
<value>
Example
OUTPUT XXX;":WAVEFORM:YINCREMENT?"
YORigin?
Query
:WAVeform:[SOURce CHANnel<N>;]YORigin?
The YORigin query returns the Y-origin value currently in the preamble.
This value is the voltage at center screen.
Returned Format
[:WAVeform:YORigin]<value><NL>
1 through the number of channels in the oscilloscope connected as one unit
<N>
(maximum of 8 channels)
Y-origin value in preamble
<value>
Example
OUTPUT XXX;":WAVEFORM:YORIGIN?"