11.5 Outside dimensions and general specification
1. Outside dimensions
LE-40MTB-E
TENSION CONTROLLER
OUTPUT
ON/OFF
MENU
SHIFT
POWER
MENU6
MENU7
ON
MENU2
MENU3
MENU4
MENU5
OFF
MENU0
MENU1
Accessories
Main unit mounting legs : One pair
Screws fixing main unit and mounting legs : M4 × 10 ,4screws
Screws of 10 mm or more are not applicable because
such screws may make contact with parts inside the
main unit.
When the unit is installed on the floor or wall, use
these screws to fix the main unit and mounting legs.
2. General and environmental specifications
Ambient temperature
Ambient humidity
Vibration resistance
Impact resistance
Supply noise resistance
Withstand voltage
Insulation resistance
Grounding
Operating atmosphere
Power switch cycles
246
X10N
MONITOR
N
SELECT
%
MODE
DISPLAY
TENSION
AUTO
MANUAL
SET
PAGE
MANUAL
ENTER
SET
CURSOR
CANCEL
228
244
256
°c
0 ~ 40
during operation
80% RH or less ( no condensation)
10 to 55 Hz, 0.5mm (4. 9m / s
2
98m / s
, 3 times in each of three axis directions.
By noise simulator with 1,000 Vp-p noise voltage, 1 µs noise width and 30 to 100 Hz
cycle.
1,500V AC, 1 minute
5MΩ or more by 500V DC megger
Solid grounding (100Ωor less)
No corrosive gas and little dust
Less than 20,000 times
16.5
12 MAX
15
Weight : Approximately 3.5 kg
Painting color : Munsell 7.5Y 7.5/1
during operation
2
maximum), 2 hours in each of three axis directions .
Entire terminals as a whole and between the
ground terminal.
73
140
16
80
100