External Connection Diagram - Mitsubishi LE-40MTB-E Instruction Manual

Tension controller
Table of Contents

Advertisement

11.2 I / O interface
+10%
AC100~240V
-15%
50/60 Hz
Power supply
Class D grounding
( 100
Ω or less )
FG on metal plate
Tensino detector
Left
Tension detector
Right
+5V
External
tension setting
*2
*2
Stall memory reset
Gain 1 input
Reel exchange
Operation/stop
The function to be assigned *1,*2
is specified by the parameter.
PSL PSN ZT
P
ZT
250V 8A
PSL
PSN
GRL
Zero/span
Zero/span
adjustment
adjustment
WHL
GRR
Zero/span
adjustment
WHR
AI1
5V
10KΩ
100KΩ
AI2
*1
100KΩ
AI3
*1
100 KΩ
AIC
1.6KΩ
Photo coupler
MC6
MC5
MC4
MC3
MC2
MC1
MCC
8V
SI MCC MC2 MC4 MC6 +5V
N
S2 MC1 MC3 MC5 AIC AI1
5V
0.1Ω
+
12V
RY
AI2 GRL RED BLK GRR SA EAP AOC NRO LSA
AI3 WHL SG
SG WHR SN EAN TMO LSB LFG
70
Power supply for
+5V
trimmers
RED
Power supply for
tension detector
BLK
S G
S G
Shielded cable
P
DC24V 4A
Powder clutch/brake
Hysteresis
N
clutch/brake
S A
Power amplifier
Servo amplifire
S N
0~±5V
EAP
E/P regulator
4~20mA
EAN
TMO
Tension
monitor output
0~5V
AOC
New rell
preset output
NRO
0~5V
S 1
DC12V 2A,Rating:10s
Auxiliary powe output
S 2
0.1Ω
Z T
Zero tension
detection output
Z T
LSA
LSA
LSB
LSB
LFG
LFG
0~5V
FX2N
-485BW

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents