Calling Up Engineer Screen - Mitsubishi LE-40MTB-E Instruction Manual

Tension controller
Table of Contents

Advertisement

5.3 Calling up engineer screen

• Follow this operation to make changes from the state of initial setting.
• Enter the password on the password screen. Press the enter key to enter the engineer screen.
Reel diameter
monitor or tension
monitor screen.
P
A
S S W O R D
Enginneer screen
S
E
T T I N G
S W I T C H
The control output by the manual torque and the stall setting are set
by the following standard .
Manual
torque
Stall
New reel preset
Fmax =
• Obtaining stall value and new reel torque by operating actual machine
Operate the machine in automatic control mode with the target tension . Display the
output on the output indicator (4-digit, 7-segment display ).
Read the output value where the reel diameter is close to the initial diameter . It is
recommended to use this value as the stall value .
Complete
initial setting
S E T → # # # # #
Numeric input
4095
ENTER
S E L E C T
M E N U
:
T E N S I O N
:
S
E
T T I N G
S E L E C T
M E N U
:
O T H E R
Seting screen
Standard of volume set output
Feed control
D
F
N =
× 100
D
F
max
max
~
D
F
0
0
N =
× 100
D
F
max
max
Ratings torque of actuators
The maximum use torque of actuators
S E T
N U M B E R
Enter"4095 " or the value
registered in the initial
setting as the password
(Refer to page 8.)
Error input
message
B Y
C U R S O R
S T R T
.
S T P :
R E E L
M E N U
B Y
C U R S O R
:
G A I N
For setting of these items,refer to the initial setting.
Feed control
Dmax : Maximum diameter
F
D
N =
× 100
F
F
max
D0
~
F
F
N =
× 100
F
max
× The maximum drive tension
15
C H G :
:
4 0 M D
: Diameter
: Control tension
: Initial diameter
: Average drive tension

Hide quick links:

Advertisement

Table of Contents
loading