5. Setting
To execute the CC-Link with the LE-40MTB-E, use the "PC-link " screen in " Other " on the engineer
screen for setting.
Reel diameter
monitor or tension
monitor screen.
P
A
S S W O R D
S
E
T T I N G
S W I T C H
P
C
- L I N K
U N U S E
5. Handling the link data
• When the link data is written into the LE-40MTB-E, the data whose data are for Menu 0 and for system
data ( items marked with
are saved. Other data are not saved. When the data other than Menu 0 must be saved, save such
data on the master programmable controller side.
• When the data is written in the LE-40MTB-E through link, it is written directly in the control table. Ac-
cordingly, the data in the menu table where the data of MENU 1 to MENU 7 are memorized are not
updated. Because saving of the data for Menu 0 is controlled in the control table, the data area for
Menu 0 is saved automatically. But because saving of the data for other menus is controlled in the
menu table, the data obtained through link is not saved automatically.
• When you want to save the data for other than Menu 0 in the LE-40MTB-E, you must perform the man-
ual operation. (Press the [ENTER] key twice. Refer to page 46 for the details.)
When there are more than eight menus, keep the data in the master programmable controller and use
MENU 0 in the LE-40MTB-E.
• When the switch-over menu No. data (Set value No. 70) is updated on the master programmable con-
troller side while the LE-40MTB-E is stopped (MC1 = OFF), the menu can be switched over through
link.
• For all the link data, the priority is given to the last data. When the data currently set is updated through
link, the updated data becomes effective immediately after the LE-40MTB-E receives it. When two or
more set values are transferred in the same timing at the same time, the priority is given to the one
having a larger data register No. in the link area. (The data whose device No. is larger will be processed
later.)
• The contact data is an OR command. Accordingly, it becomes effective if the input on the LE-40MTB-
E side is turned on. To control ON-OFF of the contact signal through the link, set the LE-40MTB-E
input to OFF.
Complete
initial setting
S E T → # # # # #
S E L E C T
M E N U
:
T E N S I O N
:
S T R T
S
E
T T I N G
S E L E C T
R E E L
C H G :
R E E L
S E L E C T
P C - L I N K
:
F X - P A R A L :
N E T /
Select " CC-Link "
and
in the system column of the table on page 81 and 82 ) exclusively
56
S E T
N U M B E R
B Y
C U R S O R
.
S T P :
R E E L
M E N U
B Y
C U R S O R
:
M R N U
M
I N I :
C C - L I N K
C H G :
:
O T H R E