11. Specifications
11.1 I / O Specifications
Items
Input
Power
supplies
Output
Input
Contact
signals
Output
Analog
Input
signals
Terminal
100 ~ 240V AC +10 ~ –15% 50/60 Hz 400VA
PSL
Power fuse (250V 8A) built in
PSN
Allowable instantaneous power interruption:10ms
S1(+)
Auxiliary power supply: 12 VDC, 2 A, Rating: 10 s
S2(–)
RED(+)
Power supply for tension detectors
BLK(–)
+5V(+)
Service power supply for external trimmer
5V DC, 50mA or less
AIC(–)
MCC
Contact input common terminal
Operation/stop
MC1
ON=Automatic operation, OFF=Stop
Reel exchange signal
MC2
OFF=Reel A, ON=Reel B
MC3
Gain 1
Gain 1 is effective during ON.
Stall memory reset
MC4
One-shot input for approx. 0.5 s
Gain2
Inching
MC5
OUT remote : Control output is ON during ON.
Cut torque
EXT tension : ON -------- External input is valid.
MC6
Each function is assigned by parameter.
• Zero tension detection output.
Set value : 0~1999 N (199.9 kgf)
ZT
• Output becomes ON when tension does not exceed set value.
• Output is always OFF when "0" is set. (However, output becomes ON
regardless of set value and tension when watch dog timer is actuated.)
ZT
• 250V AC, 0.5A or 30V DC, 0.5A
Tension detector signal.
GRL
Left
• Number of detectors(one or two) is specified by parameter.
WHL
• Connection varies depending on load type(compression or ten-
sion).
GRR
• When one detector exclusively is used,terminals[GRL] and
Right
WHR
[WHL] must be short-circuited.
External tension setting
AI1
0 ~ 5 VDC corresponding to 0 ~ full-scale tension
Internal resistance
AIC
Recommended trimmer: 10 kΩ
Specifications
: Gain 2 is effective during ON.
: Lower output limit is effective.
Stall memory update is stopped.
: Lower output limit is effective during ON
(for cutter).
OFF------- Setting from the panel is valid.
GR=green,
: 100 kΩ
68
8V DC,
4mA/terminal
WH=white